Skip to main content
. 2023 Sep 20;8(3):61–83. doi: 10.25646/11666

Table 2.

Components of the home visit examination at month 12 follow-up

Source: Gesundheit 65+

Component Device Measurement
Anthropometric measures
   Height Portable Stadiometer Seca 213 Height in cm, accuracy of measurement: 0.1 cm
   Weight Personal scale Seca 208 Weight in kilos, accuracy of measurement: 0.1 kg
   Calf circumference Ergonomic measurement tape (Medical product), Seca 201 Circumference in cm on left calf, accuracy of measurement: 0.1 cm
Blood pressure and heart rate
   Resting blood pressure Mobil-O-Graph®, IEM GmbH Standardized protocol, three automated measurements in a sitting position after resting
Physical function
   Isometric hand grip strength Smedley dynamometer, Scandidact, Denmark, 100 kg Maximum grip strength achieved in four examinations alternating right and left, accuracy of measurement: 0.5 kg
Cognitive function
   Excecutive function Letter Digit Substitution Test [70] Measuring the number of digits correctly substituted within 60s
   Verbal episodic memory Word list from the German language version of consortium to establish a registry for Alzheimer’s disease [CERAD, 71] Measuring the number of correctly recalled words per trial (Trial 1 – 3 immediate recall, Trial 4 delayed recall)
Medication use
   Current medication use (past 7 days) „Arzneimittel-Erfassungs-Datenbank“, AmEDa, Medication Recording Database On-site medication review via a computer-assisted personal interview and automated barcoding
Statutory health insurance data
   Personal health insurance number Card reader for electronic health cards; software for asymmetrical encryption of personal health insurance number Linkage to health insurance records such as diagnosis codes and drug prescription up to four years prior to examination