Skip to main content
. 2023 Oct 4;15:100395. doi: 10.1016/j.jvacx.2023.100395

Table 1.

Laboratory tests performed during the evaluation of the immunization error in an infant of 6 months old (HCRP, 2022).

Day 1 Day2 Day4 Day15 Day71
D-DIMER
(ug/mL)
1.81 3.71 0.53 0.24
0.4
NT-proBNP
(pg/ml)
419
INR 0.87 1.09 1.25
CRP
(mg/dL)
53.9
(<2.8)
6.39
(<1.0)
1.54
(<1.0)
TROPONIN Negative
CKMB
(u/L)
20 (<25,0)
CBC HB 11,3
HT 33
WBC: 9900
neut: 9,7%(1,9)
lymph 70,5% (7,0)
eos 3 % (0,3)
PLT 491.000
HB 10.7
HT 32
WBC: 7800
neut:13 %(1,0) lymph:75 %(5,9)
eos 5.5 % (0,4)
PLT: 519.000
HB 10,2
HT 30,2
WBC: 9000
neut:23 %(2,0)
lymph:70 %(6,3)
eos 3 % (0,27) PLT: 463.000
HB 10,2
HT 30
WBC: 6100
neut:50 %(2,1)
lymph:36 %(2,1) eos: 0 % PLT:224.000
LIVER ENZYMES (U/L)
CREATININE (mg/dL)
AST 72
0.19
AST 72
ALT 27
0.20
FIBRINOGEN (mg/dL) 279 241