Table 2.
Surgical details for Cabrol procedures
Patient number | Year | Operation | Cap material | Conduit used | Drainage site |
---|---|---|---|---|---|
1 | 2004 | Apical aortic conduit | Bovine pericardium | Apical-aortic conduit (22 conduit, 21 CE valve) 10-mm Hemashield graft |
Left subclavian vein |
2 | 2006 | Redo aortic root | Bovine pericardium | Direct opening under patch | Right atrium |
3 | 2008 | Redo aortic arch | Bovine pericardium | Tent only | No outflow required—patch provided adequate hemostasis |
4 | 2008 | Redo aortic arch | Bovine pericardium | Tent only | No outflow required—patch provided adequate hemostasis |
5 | 2008 | Redo aortic arch | Bovine pericardium | 8-mm Dacron graft | Innominate vein |
6 | 2010 | Redo ascending replacement | Bovine pericardium | Direct opening under patch | Right atrium |
7 | 2011 | Aortic root | Bovine pericardium | Valved Contegra graft | Right atrium |
8 | 2011 | Aortic root | Bovine pericardium | Valved Contegra graft | Innominate vein |
9 | 2013 | Aortic root | Bovine pericardium | Valved Contegra graft | Innominate vein |
10 | 2013 | Redo aortic root | Bovine pericardium | Direct opening under patch | Right atrium |
11 | 2013 | Ascending replacement | Bovine pericardium | Cryopreserved homograft vein | Right atrium |
12 | 2013 | Aortic root | Bovine pericardium | Direct opening under patch | Right atrium |
13 | 2016 | Aortic root | Bovine pericardium | Cryopreserved homograft vein | Right atrium |
14 | 2016 | Aortic root | Bovine pericardium | 6-mm Gore-Tex graft | Innominate vein |
15 | 2016 | Ascending replacement | Bovine pericardium | Direct opening under patch | Right atrium |
16 | 2016 | Redo ascending arch | Bovine pericardium | 8-mm Hemashield graft | Innominate vein |
17 | 2020 | Ascending replacement | Bovine pericardium | Femoral vein homograft | Innominate vein |