Table 4. Comparison of VNC images derived from low-dose and full-dose contrast images.

Item VNClow VNCfull TNC P value
VMC
   AAO 3.48±9.16* 21.10±12.94* −4.40±16.28 <0.001
   DAO −0.04±9.27 22.58±12.96* −4.73±11.92 <0.001
   AA 1.45±7.00* 25.57±11.63* −6.15±9.01 <0.001
VMR
   AAO 1.17±0.33 1.92±0.81* 1.00±0.41 <0.001
   DAO 1.02±0.26 1.79±0.61* 0.93±0.21 <0.001
   AA 1.04±0.17* 1.65±0.32* 0.89±0.16 <0.001
VMP
   AAO 0.17±0.33 0.92±0.81* 0.01±0.41 <0.001
   DAO 0.02±0.61 0.79±0.61* −0.06±0.21 <0.001
   AA 0.44±0.17* 0.62±0.32* −0.01±0.16 <0.001

Data are presented as the mean ± standard deviation. *, significant difference from the TNC group; , significant difference from the VNCfull group. TNC, true noncontrast; VNC, virtual noncontrast; VMC, vessel-muscle contrast; AAO, ascending aorta; DAO, descending aorta; AA, abdominal aorta; VMR, vessel:muscle ratio; VMP, vessel-muscle percentage.