Skip to main content
. 2023 Aug 31;13(10):6814–6826. doi: 10.21037/qims-23-477

Table 2. Information on PET/CT or SPECT scanning in this systematic review and meta-analysis.

First author Year Modality Ligand Dose (MBq)
Jahn (33) 2021 Discovery MI, GE Healthcare 68Ga-DOTATOC 167±21
Gålne (24) 2019 Discovery 690 scanner (GE Healthcare) 68Ga-DOTATATE 2.5 MBq/kg
Li (32) 2019 Discovery NM/CT 670, GE 99mTc-HYNIC-TOC 370
Aalbersberg (23) 2019 Gemini TOF PET/CT (Philips) 68Ga-DOTATATE 100
Cherk (31) 2018 Discovery 690 GE Healthcare or Siemens Biograph Healthcare 68Ga-DOTATATE 85–307
Ayati (22) 2018 Gemini TOF PET/CT scanner (Philips) 68Ga-DOTATATE 110–185
Haug (30) 2011 Gemini PET/CT scanner (Philips) 68Ga-DOTATATE 200
Janson (29) 1999 SPECT (Nuclear Diagnostics, Hagersten, Sweden and London, UK) 111In-pentetreotide 144 [114–238]
Dörr (28) 1993 Siemens Orbiter 7500 Gamma Camera 111In-pentetreotide 137 [105–237]

Data are presented as mean ± standard deviation, median [interquartile range] or n. PET/CT, positron emission tomography/computed tomography; SPECT, single photon emission computed tomography; MI, molecular imaging; NM, nuclear medicine; TOF, time of flight; 68Ga, Gallium-68; 99mTc, Technetinum-99m; 111In, Indium-111.