Skip to main content
. 2023 Jul 6;4(2):100363. doi: 10.1016/j.xops.2023.100363

Table 1.

Data Set Characteristics and the Train/Validation/Test Number of Images for the Experiment for One-Shot Artery and Vein Segmentation

Data set No. Train/Validation/Test No. Location Field Size Eye Disease Camera
RITE 40 1/19/20 Macula 45° 565×584 DR CR5 non-mydriatic 3CCD camera (Canon)
HRF 45 1/22/22 Macula 45° 3504×2336 DR, glaucoma Canon CR-1 nonmydriatic fundus camera (Canon)
AV-WIDE 30 1/14/15 Macula 200° 1300×800
2816×1880
1500×900
DR Optos 200Tx (Optos PLC)
LES-AV 22 1/10/11 Optic-disc 30°–45° 1620×1444
1958×2196
Glaucoma Visucam ProNm fundus camera with a ZK-5 (PRO NM/NMFA) 5 MP sensor
PortableAV 30 1/14/15 Macula 50° 4096×3072 Normal, DR, AMD Mediworks camera (Mediworks)
DRSplusAV 20 1/9/10 Macula
Optic-disc
40°×45° 2592×1944 Normal, myopia iCare DRSplus (Centervue)

AMD = age-related macular degeneration; DR = diabetic retinopathy.