Flow cytometer (BD LSR Fortessa X-20)
Reagent | Laser (excitation nm) | Emission filter (nm) |
---|---|---|
Viability Dye - LIVE/DEAD Fixable Blue | UV (355) | 450/50 |
MitoSOX RED (MSR) | Blue (488) | 710/50 |
MitoView Green (MVG) | Blue (488) | 530/30 |
ThiolTracker Violet (TTV) | Violet (405) | 525/50 |
SOD1/Cu-Zn SOD Antibody / Goat anti-Rabbit IgG (H + L) Secondary Antibody, DyLight 405 | Violet (405) | 450/50 |
Brilliant Violet 605 anti-human CD16 Antibody | Violet (405) | 610/20 |
BUV395 Mouse Anti-Human CD56 | UV (355) | 379/28 |
BV650 Mouse Anti-Human CD21 | Violet (405) | 670/30 |
BV786 Mouse Anti-Human CD19 | Violet (405) | 780/60 |
Alexa Fluor 700 Mouse Anti-Human CD27 | Red (640) | 730/45 |
PE-Cy7 Mouse Anti-Human CD45RO | Yellow/Green (561) | 780/60 |
PE-CF594 Mouse Anti-Human CCR7 (CD197) | Yellow/Green (561) | 610/20 |
BUV805 Mouse Anti-Human CD8 | UV (355) | 800/40 |
BV711 Mouse Anti-Human CD4 | Violet (405) | 710/50 |
APC-H7 Mouse Anti-Human CD3 | Red (640) | 780/60 |
Anti-Nrf2 Antibody A-10 | Red (640) | 670/30 |