Accuracy of FBCSP-based brain-state classification across five participants’ pre- and post-exercise in-ear EEG data

Frequency bands (Hz) Accuracy (%)
Eyes open Eyes closed
Fully relaxed Immediately post-exercise Fully relaxed Immediately post-exercise
4–28 (3 bands) 64.06 84.40 63.25 88.45
4–36 (4 bands) 63.37 86.45 64.11 90.34
4–44 (5 bands) 63.94 89.77 66.11 91.48
12–44 (4 bands) 62.74 89.77 65.31 90.91
20–44 (3 bands) 63.25 89.71 66.06 90.11

Each of the participants’ brain-state classification data are given in Supplementary Table 2.