Skip to main content
. 2023 Oct 16;9(10):e20997. doi: 10.1016/j.heliyon.2023.e20997

Table 2.

Tolerable values (log KPotAC+) of the designed AC-PM-MWCNTs and AC-PM-MWCNTs-Al2O3 nanocomposite sensors estimated by separate and mixed solution techniques using 1.0 × 10−3 mol L−1AC and a foreign material (1.0 × 10−3 and 1.0 × 10−1 mol L−1) solution for the two methods, respectively.


Interferents
AC-PM-MWCNTs sensor
AC-PM-MWCNTs-Al2O3 nanocomposite sensor
SSM MSM SSM MSM
Mg2+ −2.6 −1.4 −3.4 −2.9
Ca2+ −2.4 −2.4 −4.7 −4.3
Ti4+ −2.7 −3.4 −4.2 −4.6
Na+ −2.2 −7.1 −3.2 −3.5
Cu2+ −2.1 −9.7 −3.8 −2.8
K+ −2.6 −2.7 −4.6 −4.2
Cr3+ −2.0 −2.1 −3.3 −3.9
Al3+ −2.6 −2.6 −3.2 −2.7
Zn2+ −2.4 −2.5 −3.8 −3.8
Lactose −2.7 −2.7 −3.5 −4.2
Sucrose −2.1 −2.1 −4.1 −3.6
Histidine −2.6 −2.7 −4.2 −5.2
Glycine −2.9 −2.5 −3.3 −3.4
Magnesium −2.4 −2.3 −3.6 −3.1
stearate −2.3 −2.4 −3.1 −4.1