What is Known:

• Targeted Neonatal Echocardiography is increasingly applied to measure cardiac output in critically ill neonates and serial assessments are performed to assess the trend in changes in cardiac output.

• Noninvasive measurement using velocity time integral to calculate cardiac output is commonly performed. However, location of Doppler sample gate to measure ventricular outflow tract velocity time integral is not consistent.

What is New:

• Statistically significant changes in measured velocity time integral and cardiac output are noted based on the location of Doppler gate sampling.

• To monitor the cardiac output for trending, it is important to be consistent with regards to the location of the Doppler sample gate to assess changes in cardiac output in critically ill newborns.