Supplemental Digital Content is Available in the Text.
Key Words: boxing, mixed martial arts, hand speed, accelerometer, wearable technology
Abstract
Omcirk, D, Vetrovsky, T, Padecky, J, Malecek, J, and Tufano, JJ. Validity of commercially available punch trackers. J Strength Cond Res 37(11): 2273–2281, 2023—This study determined how well data from commercially available punch trackers (Corner, Hykso, and StrikeTec) related to gold-standard velocity and force measures during full-contact punches. In a quasi-randomized order, 20 male subjects performed 6 individual rear straight punches, rear hooks, and rear uppercuts against a wall-mounted force plate. Punch tracker variables were compared with the peak force of the force plate and to the peak (QPV) and mean velocity (QMV) assessed through Qualisys 3-dimensional tracking. For each punch tracker variable, Pearson's correlation coefficient, mean absolute percentage error (MAPE), and mean percentage error (MPE) were calculated. There were no strong correlations between punch tracker data and gold-standard force and velocity data. However, Hykso “velocity” was moderately correlated with QMV (r = 0.68, MAPE 0.64, MPE 0.63) and QPV (r = 0.61, MAPE 0.21, MPE −0.06). Corner Power G was moderately correlated with QMV (r = 0.59, MAPE 0.65, MPE 0.58) and QPV (r = 0.58, MAPE 0.27, MPE −0.09), but Corner “velocity” was not. StrikeTec “velocity” was moderately correlated with QMV (r = 0.56, MAPE 1.49, MPE 1.49) and QPV (r = 0.55, MAPE 0.46, MPE 0.43). Therefore, none of the devices fared particularly well for all of their data output, and if not willing to accept any room for error, none of these devices should be used. Nevertheless, these devices and their proprietary algorithms may be updated in the future, which would warrant further investigation.
Introduction
As combat sports require training strategies to increase hand speed (21) and punch force (10), quantifying these metrics during training is necessary to objectively determine whether the training program is effectively improving performance in these areas (13). In the laboratory, punch performance has been assessed using 3-dimensional kinematics (5,8,20,34) and force plates (22,23,26) to determine punching speed and punching impact, respectively. Indeed, those laboratory devices are commonly used in research as the gold measurement standard. However, it is impractical to use these devices to assess punch performance in real-life training such as sparring, shadow boxing, and bag work, which is where the majority of punch-specific training volume occurs. Because of the complexity, high prices, and lack of feasibility of those pieces of laboratory equipment, portable user-friendly devices can serve as an alternative and have become commercially available (40).
In recent years, accelerometers have become increasingly popular during sports training and physical activity tracking of all types (18,36). The majority of people who use these devices likely are not members of a scientific or academic population and would likely be attracted to the low cost and ease of use compared with devices intended for laboratory conditions (3,7,33). Furthermore, commercially available devices often analyze data within their own proprietary software, so the end user receives an understandable data output without the need for tedious analysis procedures. As a result, different devices include unique user interfaces (11) and a wide range of different data, despite the internal technology of those devices likely being quite similar (31,39). However, as each device and its accompanying software is intended for specific purposes, the algorithms within likely would not be transferable between activities. For example, an accelerometer used to measure running or weightlifting performance likely could not be used in other sports modalities such as striking during combat sports (15). Therefore, specific accelerometers, known as punch trackers, have been developed to specifically assess punch performance (33).
Punch trackers are said to measure punch count (30), punch type (30), punch velocity (27), and punch power (26) in addition to other variables that companies seem to include with their own arbitrary units such intensity scores, PIQScores, and G-Force (30). Previous research has shown that certain punch trackers are able to accurately quantify punch count and punch type depending on training experience, with the trackers seemingly able to better detect straight punches (compared with hooks and uppercuts) and punches in trained punchers (compared with untrained, regardless of the punch type) possibly because of better punch technique that may better fit the proprietary algorithms (30). Although those findings are useful, that study did not assess the effect of training experience on punch velocity and punch force, which are likely more interesting metrics for those wishing to actually monitor their training volume and intensity in practice.
Apart from that study, another one showed that a non–punch-specific accelerometer can be used to assess punch velocity (19), but that study only included straight punches and a wired accelerometer system, both of which have obvious limitations in real-life training. In addition, previous research has shown that a different non–punch-specific accelerometer was more valid for faster movements (during a barbell back squat) compared with slower movements because the device may have had difficulty identifying the beginning of the movement during slower velocities (4). As the technology within may be similar, it is possible that punch trackers may not correctly identify and analyze punches thrown at different intensities. Furthermore, although the amount of research on punching sensors has recently been increasing to include various punch types and custom-built wireless systems (26,27), there is still a lack of published data on the validity of commercially available punch trackers. From this point of view, research is necessary to validate the ability of commercially available trackers to accurately measure and provide end user data regarding punch force and velocity. This leads to the purpose of this study, which was to assess the validity of 3 commercially available trackers for tracking punch velocity and force during different types of punches thrown by trained and untrained punchers at higher and lower intensities.
Methods
Experimental Approach to the Problem
To investigate the validity of 3 commercial punch trackers (Hykso, StrikeTec, and Corner), subjects performed a series of punches (rear straight [RS], rear hook [RH], and rear uppercut [RUC]) during a single laboratory session. All these trackers provide some type of velocity measurement; however, it is not always known whether they assess mean velocity, peak velocity, acceleration, or another related variable. Furthermore, one of these trackers (Corner) provides a variable called Power G, which may not only relate to punching velocity but also to force. However, again, it is not known exactly where that variable comes from or how it is calculated. Therefore, the criterion validity of the punch trackers was assessed against 2 commonly used laboratory devices that directly measure velocity and force: an optical 3-dimensional motion capture system and a wall-mounted force plate.
Subjects
Twenty physically active men volunteered in this study (27.8 ± 5.9 years [range: 19-44], 83.2 ± 11.8 kg, 180.1 ± 8.5 cm). As mentioned in the Introduction, it is possible that punching experience may also affect the metrics provided by the trackers that were analyzed in this study. Therefore, an equal number of trained punchers (n = 10) and untrained punchers (n = 10) participated in the study. The trained punchers were experienced in combat sports involving punching for at least 1 year and had completed at least 1 competition bout in any discipline that involved punching (e.g., boxing, kickboxing, and mixed martial arts). The untrained punchers had not participated in any formal competition. Subjects had no recent injuries that would affect or be exacerbated by the study protocols. Before starting the procedures, subjects were provided with information about the risks, benefits, and procedures of the study and gave their written informed consent in accordance with the ethical requirements of the Ethics Committee of Charles University, Faculty of Physical Education and Sport (127/2019), and the Declaration of Helsinki.
Procedures
All procedures were performed during 1 session and consisted of a general warm-up; fitting with boxing gloves, wraps, and punch trackers; instructions and technique practice; a specific warm-up of shadow boxing; individualized force plate adjustments; punches performed at 50% of their perceived maximum intensity; and maximal effort punches.
General Warm-up
All subjects performed a general warm-up that included 90 seconds of rope skipping, 10 repetitions of shoulder and elbow forward and backward circles for each side, 10 front and side leg swings on each leg, 10 lunges on each leg, and 45 seconds of boxing stepping.
Fitting With Boxing Gloves, Wraps, and Punch Trackers
Immediately after the general warm-up, standard 10-ounce boxing gloves and 2.5-meter boxing wraps were used to secure the punch trackers according to the manufacturers' guidelines. The trackers were attached to the wrist on the surface of the wrist extensors. Specifically, Hykso and StrikeTec were inserted directly under the wraps, whereas Corner was first inserted into a tailor-made wristband provided by the manufacturer and then covered by the wraps and glove. Because the punch trackers have the identical recommended placement, they were not used simultaneously, resulting in 3 separate sets of punching, 1 per tracker. To avoid any potential order or learning effect (primarily for the untrained punchers), the order of punch trackers was quasi-randomized for each subject.
Instructions and Technique Practice
All subjects (trained and untrained) were provided the same verbal and physical instructions on how to perform individual punches and performed 3 minutes of guided technique practice. The subjects stood behind the researcher and performed the punches as modeled by the researcher. During that procedure, the subjects were supervised and potentially corrected to achieve proper technique. Considering the aims of this study, it was not imperative that every punch was performed perfectly, but it was necessary to not allow punches to be thrown in unorthodox trajectories that may not be recognized by the trackers.
Specific Warm-up
After completing the standardized technique practice, subjects performed 3 rounds of shadow boxing with 5 minutes of rest between rounds. Each round of shadow boxing included 54 punches of each punch type, serving both as a specific warm-up and additional familiarization with the punching techniques. The same verbal and visual instructions were provided for each subject regardless of experience level. The data from these shadow-boxing rounds were previously analyzed to report the ability of the trackers to correctly recognize different shadow-boxing punches in various combinations (30).
Individual Settings
The wall-mounted force plate was adjusted for each subject and each punch type (Figure 1), so that they would be aiming in the center of the force plate that was placed at chin-height, as is often the aim during boxing (28). For RS, subjects stood in a normal staggered boxing stance at a self-selected distance from the force plate, and the center of the force plate was at chin-height (22). For RH, the subjects stood to the side of the force plate to where the fist contacted the force plate with approximately a 90-degree elbow angle at the height of the subject's chin-height. For RUC, the subjects stood in a boxing stance in front of the force plate, and the angle and height of the force plate were adjusted to that there was approximately a 90-degree elbow angle when the fist was in contact with the force plate that was positioned at chin-height.
Figure 1.

Three reflective markers attached on the boxing glove (A) and the force plate set-up for rear straight (B), rear hook (C), and rear uppercut (D).
Familiarization Punching the Force Plate
Before performing the individual types of measured punches, subjects performed 5 trials of each on the force plate with progressively increasing effort. The progressively increasing punching effort provided an experience how it feels to punch the force plate with maximal effort and avoid any apprehension of subjects. In addition, the force plate was covered by padded cover to avoid potential injury because of high impacts of the fist and the force plate. As the purpose of this study was not to assess peak performance, but to assess the ability of the punch tracker data to resemble gold-standard force and velocity data, this degree of familiarization was deemed sufficient. Therefore, during the punches with maximal effort, the subjects have been instructed to subjectively punch as fast and as hard as possible.
Measured Punches
The subjects performed 6 punches for each punch type (the order of which was quasi-randomized among subjects). To determine whether various speeds and intensities of the punch would affect the resultant punch tracker data (i.e., meeting required thresholds within their algorithms), 3 punches were first performed with an estimated 50% of maximal effort, followed by 3 punches with maximal effort. A constant time of 3 seconds was provided between punches, so the subjects could fully return to a stable orthodox boxing stance.
Data Acquisition and Data Analyses
Data Acquisition
Three commercially available punch trackers were used in this study: Corner (Corner Boxing Trackers, Corner Wearables Ltd., Manchester, United Kingdom, v1.3.1), Hykso (Hykso Wearable Punch Trackers, Hykso Inc., CA, v1.6), and StrikeTec (StrikeTec Boxing Sensors, StrikeTec, TX, v1.4.4). Although these types of devices likely include microcontroller, accelerometers, gyroscopes, and magnetometers (1), the specifications of the punch trackers were not publicly available when the study was completed or when the manuscript was being prepared. The same can be said of their data filtering procedures, cutoff thresholds, and the like. Therefore, the data collected and reported in this study did not originate from raw data that we then manipulated, but were directly provided by each punch tracker's respective mobile application. The output data from Corner and Hykso were transmitted through Bluetooth to a laptop, and their respective data were exported to a .csv file and transformed to Microsoft Excel for future analysis. Data from StrikeTec were manually transcribed from its mobile application (StrikeTec Boxing) because it does not allow for direct export to a .csv file. Because of technical failures and the fact that the trackers did not always record each punch performed, data from all 20 subjects were not always included in the final analyses. Therefore, the final subject counts were as follows: Hykso (n = 20); Corner (n = 20); and StrikeTec (n = 12). Detailed information about the amount of included data set for each tracker is provided in Table 1 and is further explored in the discussion.
Table 1.
The actual number of punches thrown with their SD for trained punchers and untrained punchers for each tracker.*†
| Hykso | StrikeTec | Corner | ||||
| TP (n = 10) | TP (n = 10) | TP (n = 4) | UP (n = 8) | TP (n = 10) | UP (n = 10) | |
| RS | 60 ± 0.0 | 60 ± 0.0 | 23 ± 0.4 | 42 ± 1.0 | 60 ± 0.0 | 59 ± 0.3 |
| RH | 57 ± 0.6 | 57 ± 0.5 | 24 ± 0.0 | 46 ± 0.7 | 60 ± 0.0 | 47 ± 1.8 |
| RUC | 58 ± 0.6 | 58 ± 0.6 | 22 ± 0.5 | 42 ± 0.8 | 53 ± 0.3 | 56 ± 1.2 |
The standard set for each punch type consisted of 6 punches for RS, RH, and RUC, respectively. Thus, although it seems as if ∼50% of the StrikeTec punches are missing compared with Corner and Hykso, it should be noted that when the StrikeTec device was working properly, it collected approximately 96% of punches in TP and 90% of punches in UP.
RH = rear hook; RS = rear straight; RUC = rear uppercut; TP = trained punchers; UP = untrained punchers.
Punches were simultaneously assessed using the wall-mounted force plate and a video motion capture system. The adjustable wall-mounted force plate (Loadstar sensors, Fremont, CA) measured force at 1,000 Hz. Before the study, a standard incremental static calibration procedure was performed (ranging from 5 to 400 kg), and the calibration coefficients were updated within the data collection software. Subsequent spot checks with random static loads using calibrated weight plates were performed, which supported the validity of the force plate outputs against calibrated loads. All punches made contact with the center of the force plate, and the obtained data from the force plate were exported to a .csv file and transformed to Microsoft Excel (Microsoft Corporation, Redmond, WA) for future analysis where the peak punch force was recorded for each punch. Although the rate of force development and impulse could have been assessed from this force plate, we chose to only assess peak force to avoid the inherent drawbacks of impulse (e.g., less force applied over a longer period could equate to the same impulse as a large amount of force applied during a short period) and the lack of reliable RFD data during such rapid and ballistic movements. Therefore, we only analyzed the peak punch force.
The video motion capture system (Qualisys AB, Gothenburg, Sweden) measured peak velocity (QPV) and mean velocity (QMV) of the hand using 4 cameras (Oqus) at a frequency of 500 fps. The Qualisys system was calibrated according to the manufacturer's guidelines with a standard calibration wand and foldable L-frame, which was attached on the force plate. The researcher held wand by its handle, performing twisting movements with the handle around the force plate, until the calibration process was successful. The obtained data were exported from the Qualisys Track Manager (v2019.3) to a .csv file and transformed Microsoft Excel for future analysis. The resultant QPV and QMV were assessed through 3 reflective markers that were attached on the boxing glove (Figure 1).
Data Analyses
The test-retest reliability within individual 3-punch series was calculated using intraclass correlation coefficients (A, 1) (25). To evaluate the relationship between the metrics recorded by the trackers and the gold-standard criteria (either force measured from the force plate or velocity measured through motion capture system), Pearson's correlation coefficient (r) accompanied with the lower and upper bounds of the 95% confidence interval was calculated. The magnitude of correlations was described as follows: 0.00 to 0.30, negligible correlation; 0.30–0.50, low correlation; 0.50–0.70, moderate correlation; 0.70–0.90, high correlation; and 0.90–1.00, very high correlation (16). For metrics whose agreement was less than 0.50, no further analyses were performed. However, for the metrics whose degree of agreement was classified as at least moderate (r > 0.50), the percentage error for each punch was calculated as a difference between the tracker data and the criterion data divided by the criterion. The percentage errors and their absolute values were averaged to compute the mean percentage error (MPE) and the mean absolute percentage error (MAPE), respectively. The MPE value assesses the degree of overall overestimation or underestimation of the tracker against the criterion, whereas the MAPE value provides the most relevant and comparable indicator of individual error because it accounts for both overestimation and underestimation. For example, during the data acquisition of 2 punches, if the tracker showed for the first punch a mean velocity of 8 m·s−1 and the criterion mean punch velocity was 10 m·s−1 (percentage error −20%), and if the second punch was 12 m·s−1 and the criterion was 10 m·s−1 (percentage error +20%), the MPE would be 0. Thus, the MPE value would indicate that the tracker neither underestimates nor overestimate, but we cannot say anything about its performance in individual cases. In the same scenario, the MAPE would be 20%, thus showing that the tracker is not very accurate. However, the MAPE value alone would not allow us to say whether the punch tracker systematically underestimated or overestimated the criterion value.
For metrics with an MPE within 10% (6), Bland-Altman plots were constructed to evaluate the mean bias, heteroscedasticity, and the limits of agreement between the tracker and the criterion for individual punch types. Heteroscedasticity was explored using Pearson's correlation coefficients between the absolute differences and the mean values (2) and by visual inspection of a regression line fitted to the Bland-Altman plots. The limits of agreement were calculated as 2 SDs from the mean. Finally, linear mixed-effects models were used to assess the effect of training experience, punch intensity (50 and 100%), and punch type on the percentage error.
Results
The correlations between punch tracker data and the gold-standard velocity and force data are shown in Table 2. None of the data from Hykso, Corner, or StrikeTec were highly correlated with the gold-standard velocity or force data.
Table 2.
The Pearson's correlation and confidence intervals (95%) for the Hykso, StrikeTec, and Corner and their nondefined velocity/speed or power values compared against gold-standard peak velocity, mean velocity, and peak punch force values for all 3 punch types combined.*
| Hykso | StrikeTec | Corner | ||
| Peak velocity | Speed | Power G | Speed | |
| QPV | r = 0.61 (0.54–0.68)† | r = 0.55 (0.44–0.64)† | r = 0.58 (0.51–0.65) | r = 0.03 (−0.08 to 0.13) |
| QMV | r = 0.68 (0.62–0.74)† | r = 0.56 (0.45–0.65)† | r = 0.59 (0.51–0.65) | r = −0.05 (−0.16 to 0.05) |
| FP | r = 0.23 (0.13–0.33)† | r = 0.36 (0.23–0.48)† | r = 0.28 (0.17–0.37) | r = 0.43 (0.34–0.52) |
FP = peak punch force; QMV = mean velocity; QPV = peak velocity.
p < 0.001.
For the metrics whose degree of agreement was at least moderate (r > 0.50: Hykso peak velocity, Corner Power G, and StrikeTec velocity), the MPE and MAPE were calculated (Table 3). Then, based on the MPE values (<10%), Bland-Altman plots, with the mean difference and their limits of agreement, were constructed only for QPV and each punch type for both Hykso peak velocity (Figure 2) and Corner Power G (Figure 3). Heteroscedasticity was small but significant for both Hykso peak velocity (r = 0.21, 95% CI 0.10 to 0.31, p < 0.001) and Corner Power G (r = −0.14, 95% CI −0.24 to −0.03, p = 0.012). Therefore, the percentage error was log-transformed before entering the regression models as the outcome variable.
Table 3.
Mean percentage error and mean absolute percentage error for Hykso, StrikeTec, and Corner and their variables.*†
| Hykso peak velocity | StrikeTec speed | Corner Power G | ||||
| MPE | MAPE | MPE | MAPE | MPE | MAPE | |
| QPV | −6% | 21% | 43% | 46% | −9% | 27% |
| QMV | 63% | 64% | 149% | 149% | 58% | 65% |
For reference, MPE and MAPE values closer to zero are the most desirable.
MPE = mean percentage error; MAPE = mean absolute percentage error; QMV = mean velocity; QPV = peak velocity.
Figure 2.

Bland-Altman plots for peak velocity of all punches (A), rear straight (B), hook (C), and upper cut (D). “Velocity” determined by Hykso. The solid lines indicated the mean difference between the peak velocity (mm·s−1) as assessed by Qualisys tracking manager and the outcomes of the tracker. The dashed lines represent limits of agreement (±1.96 × SD).
Figure 3.

Bland-Altman plots for peak velocity of all punches (A), rear straight (B), hook (C), and upper cut (D). “Power G” determined by Corner. The solid lines indicated the mean difference between the peak velocity (mm·s−1) assessed by Qualisys tracking manager and the outcomes of the tracker. The dashed lines represent limits of agreement (±1.96 × SD).
The linear mixed-effects model indicated that for QPV, the percentage error for Hykso peak velocity (Figure 4) and Corner Power G (Figure 5) was significantly affected by punch type (p < 0.001). Specifically, for Hykso peak velocity, there was a significant difference between RUC and RS (p < 0.001) and between RUC and RH (p < 0.001). For Corner Power G, there was a significant difference between RUC and RS (p < 0.001), RUC and RH (p = 0.028), and RH and RS (p = 0.003).
Figure 4.

The percentage error for “velocity” determined by Hykso with peak velocity assessed by Qualisys tracking manager as the gold standard. RS = rear straight; RH = rear hook; RUC = rear uppercut. Significantly greater (***p ≤ 0.001) than RS and RH.
Figure 5.

The percentage error for “Power G” determined by Corner with peak velocity assessed by Qualisys tracking manager as the gold standard. RS = rear straight; RH = rear hook; RUC = rear uppercut. Significantly greater (*p ≤ 0.05; **p ≤ 0.01; ***p ≤ 0.001) than RH and RUC.
Furthermore, the linear mixed-effects model indicated that for QPV, the percentage error was not significantly affected by training experience for Hykso, (p = 0.162) or Corner (p = 0.202). In addition, for QPV, the percentage error was not significantly affected by punch intensity (50 vs 100%) for Hykso (p = 0.405), but it was for Corner Power G (p = 0.042) (results of separate analyses for 50 and 100% intensities are reported in Supplemental Digital Content 1, http://links.lww.com/JSCR/A400). The test-retest reliability within the 3-punch series for individual trackers, punch types, and intensities varied widely from none to excellent, which is later explained in the discussion (see Supplemental Digital Content 2, http://links.lww.com/JSCR/A401).
Discussion
This study was conducted to elucidate whether commercially available punch trackers could provide data that would relate to gold-standard punch velocity and punch force. In most settings, for data to be valid, the data collection procedures must be reliable. In this study, we purposefully asked subjects of different training levels to perform various punches at different intensities, and we did not focus on whether peak performance was attained. For example, if a subject was instructed to punch at 50% of their maximum perceived effort but they in fact punched at 70%, the trial was still included in the analyses because the main purpose was to compare punch tracker data with gold-standard force and velocity data, not to compare the ability of a subject to perform a movement perfectly for multiple trials. As a result, the reliability of subjects to execute punches with the same force or velocity ranged from poor to excellent (see Supplemental Digital Content 2, http://links.lww.com/JSCR/A401). However, it is important to consider that the reliability of subjects to punch reliably does not play a role in the ability of each punch tracker to reliably provide valid data compared with gold-standard measurements. Therefore, the results of this article must be viewed from a “device reliability” perspective rather than a “subject's ability to reliably perform a movement” perspective.
Among the many results presented in this article, the main findings include the following: (a) Although none of the punch tracker data were highly correlated with any of the criterion metrics, (b) Hykso peak velocity, StrikeTec speed, and Corner Power G were moderately correlated with QMV and QPV. Furthermore, although Hykso (peak velocity) and Corner (Power G) seemed to provide data that were moderately correlated with both QMV and QPV, (c) the percentage errors for both were smaller for QPV, indicating that data from both may best represent QPV. However, (d) the punch type seemed to influence the accuracy of Corner Power G and peak velocity of Hykso. Of note, the percentage error was greater for RUC than for RS and RH. Finally, (e) the QPV percentage error was not affected by training experience or punch intensity when using Hykso. However, for Corner, the QPV percentage error was affected by punch intensity, but not training experience. Therefore, although none of the punch tracker data were highly representative of QMV or QPV, the percentage error of QPV was not largely affected by different punch types, training status, or punch intensity when using the Hykso punch tracker.
The first point to consider, which is essential to clarify before progressing in the discussion, is that the Corner and StrikeTec punch trackers did not always provide specific units of measurement for their variables, nor did they always specify whether the variables were derived from the mean or peak. As with most sport-related movements, there are instances where, e.g., peak velocity may be more important than mean velocity (or vice versa) (17,29,32,35). However, only Hykso specified whether its data represented peak or mean values (Hykso specifically states that it measures peak velocity). The lack of peak-mean specification from Corner and StrikeTec is not alarming, per se, but it is definitely something to consider when using these devices in practice. Therefore, the relatively vague “speed” terminology provided by Corner and StrikeTec will be kept constant throughout the discussion. Although we chose to stick with the “speed” variable name provided by the manufacturers, and although neither device specifies that it measures peak velocity, the percentage error (Table 3) indicates that they likely represent QPV more so than QMV. Nevertheless, it is worth noting that in addition to Hykso's specification of peak velocity, Everlast PIQ punch trackers specify that they assess average velocity, but at the time of this study, there was not an option to assess the data of individual punches or to export the data of individual punches (30), meaning they were not included in the analyses for this study. Therefore, the remaining discussion points should be considered with caution because future updates to the software, algorithms, or variable names of these punch trackers may result in different data and conclusions than those that are presented at the time that this article was being prepared.
Regarding the peak impact force, none of the punch tracker data in this study were highly correlated with peak force data from the wall-mounted force plate (r = 0.23 to 0.43; Table 2). In terms of monitoring performance and quantifying training loads, this is far from ideal because the punch trackers used in the current study do not seem to be able to accurately quantify the impacts that could occur during boxing training. Although force plates are valid devices for assessing punch impact force (22,23), it is impractical to rely on them to quantify the impact forces accrued during training. Thus, of the punch trackers tested in this study, the “speed” data from the Corner punch tracker included the highest correlation (r = 0.43) with impact force, whereas the Power G variable had the weakest (r = 0.28). This is interesting because the Power G variable would intuitively be more closely related to force, whereas Corner “speed” data should be more indicative of punch velocity. However, based on our data, it seems as if their variable names are somewhat misleading for the user because the Power G variable was better correlated with QPV (r = 0.58) and QMV (r = 0.59) than it was with impact force. Therefore, although Corner “speed” had the highest correlation to peak impact force out of all the punch tracker variables assessed, the data indicate that none of those variables seem to be representative of peak impact force.
Regarding punch velocity, our data indicate that punch trackers (i.e., indirect measures of velocity) do not fully align with direct criterion measures of velocity (i.e., 3-dimensional kinematics), which agrees with previous research (15). Specifically, Corner speed did not correlate well with QMV or QPV. On the other hand, although Hykso is likely acceptable for monitoring both peak and mean velocity (i.e., similar moderate correlations), Hykso specifies that it measures peak velocity, which agrees with the smaller percentage errors with QPV of Table 3. Considering the percentage errors (Table 3), it also seems as if Corner Power G (MPE = −9%) and StrikeTec speed (MPE = 43%) may also better represent QPV, despite having similar moderate correlations (Table 2) with both QPV and QMV (Corner Power G—QPV r = 0.58; Corner Power G—QMV r = 0.59 and StrikeTec speed—QPV r = 0.55; StrikeTec speed—QMV r = 0.56). Nevertheless, some degree of error still exists, even for Hykso, which demonstrated the smallest percentage errors of the punch trackers assessed in this study. From a practical perspective, although multiple punch trackers can provide instantaneous feedback and increase the motivation of athletes (37,38), it seems as if Hykso could be used to provide feedback for peak punch velocity, but the error would still need to be considered.
As our analyses also showed that the MPE for QPV was greater than 10% for StrikeTec speed, we only further analyzed the effect of punch type, training experience, and punch intensity on Hykso velocity and Corner Power G. Hykso seemed to have less error when detecting velocity during RS and RH punches than RUC, but Corner had variable degrees of error depending on the punch type and punch effort. To elaborate on this, Figure 2 shows that the rate of measurement error is greater when punches are thrown with faster velocities. From a practical sense, this should be considered, especially for well-trained punchers. In addition, Hykso tends to overestimate RUC against the RS and RH. The boxing punch involves the full-body kinetic chain (12) where the ankle, thigh, trunk, forearm, and hand must move in a coordinated fashion (14). Therefore, each punch type requires a unique coordination pattern and punch trajectory (9,20). Based on previous research, the training experience and punch type can affect the abilities for punch trackers to correctly recognize and assess punches (30). However, although this study shows that error was still present when assessing QPV, the percentage error was not significantly affected by training experience. Therefore, although each punch tracker likely has different algorithms to detect and assess different punch types, they are not publicly available, which means that any further discussion on the topic cannot be justified at this moment.
Among the few remaining points to be considered, the total number of punches detected by the StrikeTec punch tracker was far fewer than the Hykso and Corner devices. Table 1 shows that StrikeTec essentially did not register 50% of the punches thrown within this study, most of which were likely due to technical difficulties. This is similar to a previous study where StrikeTec punch trackers were able to detect only about 50% of straight punches and about 3% of hooks and uppercuts during shadow boxing (i.e., punching without any contact or impact forces) (30). Therefore, the ability of the StrikeTec punch trackers to provide relevant data seemed to improve in this study when punch impact occurred, which indicates that perhaps, the algorithms within the StrikeTec software may require some degree of impact to register a punch (i.e., it collected data on ∼96% of punches in TP and 90% in UP, compared with Corner [96% for TP, 90% for UP] and Hykso [97% for TP, and 97% for UP]). Nevertheless, the velocity data provided by StrikeTec were moderately correlated with QMV and QPV, but with greater percentage errors than Hykso and Corner. Furthermore, the StrikeTec analyses only included values that were present. Thus, if “null” data were included for punches that were not registered (approximately 50% of the punches thrown), the correlations would have been far weaker, which is worth considering.
Although the purpose of this study was not to recommend purchasing any of the tested trackers, it is important to consider that the presented data were obtained in the laboratory conditions with standardized procedures. The subjects performed 3 punches with approximately 50% of maximal effort and 3 punches with maximal effort for each punch type, which is in line with similar research investigating other devices during straight punches (19). The trackers do not allow the users to input any other data of the subjects, such as fist size and arm length, suggesting that the softwares use some predefined values, which could have affected the results because punch tracker velocity is likely measured as angular velocity, but reported as linear velocity that would be affected by the radius length (24). Furthermore, any attempt to alter the position of the punch trackers would have decreased the ecological validity of the study because real-world users would also likely follow the placement guidelines provided by the manufacturers. Normally, this type of laboratory-based study is the first step in validating such devices, and future research would normally take the next step to investigate the validity of a more realistic and dynamic environment. However, we cannot currently recommend that next step because these devices may perform even worse in a more dynamic real-life situation (e.g., not performing single punches at a stationary target, but striking different areas of a moving opponent).
None of the punch tracker data in this study were highly correlated with gold-standard velocity or force measures. However, although all punch trackers provided data that were moderately correlated to peak and mean velocity, Hykso seemed to have the least amount of error, which was least affected by punch type, training experience, and punch intensity. Furthermore, Corner users should know that their Power G variable likely refers to punch velocity, whereas their velocity variable may refer to something else that may be more representative of punch force. Considering our results, future developments (i.e., software and hardware updates, specifically from these manufacturers) are needed to provide valid commercially available trackers for monitoring punch force and velocity.
Practical Applications
Coaches and athletes can likely use the Hykso and Corner punch trackers to monitor peak velocity, assuming that they are willing to accept the errors that occur within (specifically Hykso's overestimation of RUC velocity). However, if not willing to accept any room for error, none of these devices should be used. Furthermore, caution should be used when working with elite punchers because the measurement of error increases when punches are thrown at faster velocities. Thus, the faster the punch, the greater the risk of a larger measurement error. When StrikeTec is able to successfully collect data, users can accept the velocity data, but nearly half of the data were missing in our study (possibly because of a faulty device, connection problems, or other unknown factors), so caution should be used. Regarding punch force, none of the variables from this study should be used to assess punch force.
Supplementary Material
Acknowledgments
This project was partially supported by university funding for students (SVV 260599), the Cooperatio Program research area SPOB, an internal grant Q41.
Footnotes
Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Web site (http://journals.lww.com/nsca-jscr).
Contributor Information
Tomas Vetrovsky, Email: tomas.vetrovsky@gmail.com.
Jan Padecky, Email: honzapadecky@seznam.cz.
Jan Malecek, Email: malecekhonza@gmail.com.
James J. Tufano, Email: tufano@ftvs.cuni.cz.
References
- 1.Aroganam G, Manivannan N, Harrison D. Review on wearable technology sensors used in consumer sport applications. Sensors 19: 1983, 2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 2.Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 26: 217–238, 1998. [DOI] [PubMed] [Google Scholar]
- 3.Balsalobre-Fernández C, Kuzdub M, Poveda-Ortiz P, Campo-Vecino Jd. Validity and reliability of the PUSH wearable device to measure movement velocity during the back squat exercise. J Strength Cond Res 30: 1968–1974, 2016. [DOI] [PubMed] [Google Scholar]
- 4.Banyard HG, Nosaka K, Sato K, Haff GG. Validity of various methods for determining velocity, force, and power in the back squat. Int J Sports Physiol Perform 12: 1170–1176, 2017. [DOI] [PubMed] [Google Scholar]
- 5.Bingul BM, Bulgan C, Tore O, Aydin M, Bal E. The effects of impact forces and kinematics of two different stances at straight punch techniques in boxing. Sci Martial Arts 13: 35–39, 2017. [Google Scholar]
- 6.Boudreaux BD, Hebert EP, Hollander DB, et al. Validity of wearable activity monitors during cycling and resistance exercise. Med Sci Sports Exerc 50: 624–633, 2018. [DOI] [PubMed] [Google Scholar]
- 7.Camomilla V, Bergamini E, Fantozzi S, Vannozzi G. Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: A systematic review. Sensors 18: 873, 2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 8.Cheraghi M, Agha Alinejad H, Arshi AR, Shirzad E. Kinematics of straight right punch in boxing. Ann Appl Sport Sci 2: 39–50, 2014. [Google Scholar]
- 9.Dinu D, Louis J. Biomechanical analysis of the cross, hook, and uppercut in junior vs. elite boxers: Implications for training and talent identification. Front Sports Act Living 2: 598861, 2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.Dunn EC, Humberstone CE, Franchini E, Iredale KF, Blazevich AJ. Relationships between punch impact force and upper- and lower-body muscular strength and power in highly trained amateur boxers. J Strength Cond Res 36: 1019–1025, 2022. [DOI] [PubMed] [Google Scholar]
- 11.Espinosa HG, Shepherd JB, Thiel DV, Worsey MTO. Anytime, anywhere! Inertial sensors monitor sports performance. IEEE Potentials 38: 11–16, 2019. [Google Scholar]
- 12.Filimonov VI, Koptsev KN, Husyanov SS, Nazarov SS. Means of increasing strength of the punch. Strength Cond J 65–66, 1983. [Google Scholar]
- 13.French D. Combat sports. In: Science and Application of High-Intensity Interval Training, Laursen P and Buchheit M, eds. Champaign, IL: Human Kinetics, 2016. pp. 227–246. [Google Scholar]
- 14.Gu Y, Popik S, Dobrovolsky S. Hand movement kinematics of boxers with different qualification levels. IJBET 28: 336, 2018. [Google Scholar]
- 15.Harris DM, Caillaud K, Khullar S, Haff GG, Latella C. The reliability of a linear position transducer and commercially available accelerometer to measure punching velocity in junior boxing athletes. Int J Sports Sci Coach 16: 200–209, 2021. [Google Scholar]
- 16.Hinkle DE, Wiersma W, Jurs SG. Applied Statistics for the Behavioral Sciences (5th ed.). Boston, MA: Houghton Mifflin, 2003. [Google Scholar]
- 17.Jukic I, García-Ramos A, Malecek J, Omcirk D, Tufano JJ. The use of lifting straps alters the entire load-velocity profile during the deadlift exercise. J Strength Cond Res 34: 3331–3337, 2020. [DOI] [PubMed] [Google Scholar]
- 18.Lake J, Augustus S, Austin K, et al. The validity of the push band 2.0 during vertical jump performance. Sports 6: 140, 2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 19.Lambert C, Beck BR, Weeks BK. Concurrent validity and reliability of a linear positional transducer and an accelerometer to measure punch characteristics. J Strength Cond Res 32: 675–680, 2018. [DOI] [PubMed] [Google Scholar]
- 20.Lenetsky S Brughelli M Nates RJ, et al. Defining the phases of boxing punches: A mixed-method approach. J Strength Cond Res 34: 1040–1051, 2020. [DOI] [PubMed] [Google Scholar]
- 21.López-Laval I, Sitko S, Muñiz-Pardos B, Cirer-Sastre R, Calleja-González J. Relationship between bench press strength and punch performance in male professional boxers. J Strength Cond Res 34: 308–312, 2020. [DOI] [PubMed] [Google Scholar]
- 22.Loturco I, Nakamura FY, Artioli GG, et al. Strength and power qualities are highly associated with punching impact in elite amateur boxers. J Strength Cond Res 30: 109–116, 2016. [DOI] [PubMed] [Google Scholar]
- 23.Loturco I, Pereira LA, Kobal R, et al. Transference effect of short-term optimum power load training on the punching impact of elite boxers. J Strength Cond Res 35: 2373–2378, 2021. [DOI] [PubMed] [Google Scholar]
- 24.McGinnis PM. Biomechanics of Sport and Exercise (2nd ed.). Champaign, IL: Human Kinetics, 2005. [Google Scholar]
- 25.McGraw KO, Wong SP. Forming inferences about some intraclass correlation coefficients. Psychol Methods 1: 30–46, 1996. [Google Scholar]
- 26.Menzel T, Potthast W. Validation of a unique boxing monitoring system. Sensors 21: 6947, 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Menzel T, Potthast W. Application of a validated innovative smart wearable for performance analysis by experienced and non-experienced athletes in boxing. Sensors 21: 7882, 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 28.Nakano G, Iino Y, Imura A, Kojima T. Transfer of momentum from different arm segments to a light movable target during a straight punch thrown by expert boxers. J Sports Sci 32: 517–523, 2014. [DOI] [PubMed] [Google Scholar]
- 29.Nuzzo JL, McBride JM, Cormie P, McCaulley GO. Relationship between countermovement jump performance and multijoint isometric and dynamic tests of strength. J Strength Cond Res 22: 699–707, 2008. [DOI] [PubMed] [Google Scholar]
- 30.Omcirk D Vetrovsky T Padecky J, et al. Punch trackers: Correct recognition depends on punch type and training experience. Sensors 21: 2968, 2021. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 31.Peake JM, Kerr G, Sullivan JP. A critical review of consumer wearables, mobile applications, and equipment for providing biofeedback, monitoring stress, and sleep in physically active populations. Front Physiol 9: 743, 2018. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Rodríguez-Rosell D, Yáñez-García JM, Sánchez-Medina L, Mora-Custodio R, González-Badillo JJ. Relationship between velocity loss and repetitions in reserve in the bench press and back squat exercises. J Strength Cond Res 34: 2537–2547, 2020. [DOI] [PubMed] [Google Scholar]
- 33.Shepherd JB, Thiel DV, Espinosa HG. Evaluating the use of inertial-magnetic sensors to assess fatigue in boxing during intensive training. IEEE Sens Lett 1: 1–4, 2017. [Google Scholar]
- 34.Stanley E, Thomson E, Smith G, Lamb KL. An analysis of the three-dimensional kinetics and kinematics of maximal effort punches among amateur boxers. Int J Perform Anal Sport 18: 835–854, 2018. [Google Scholar]
- 35.Tufano JJ Vetrovsky T Stastny P, et al. Assisted jumping in healthy older adults: Optimizing high-velocity training prescription. J Strength Cond Res 36: 1518–1523, 2020. [DOI] [PubMed] [Google Scholar]
- 36.Watkins CM, Maunder E, Tillaar Rvd, Oranchuk DJ. Concurrent validity and reliability of three ultra-portable vertical jump assessment technologies. Sensors 20: 7240, 2020. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 37.Weakley J, Till K, Sampson J, et al. The effects of augmented feedback on sprint, jump, and strength adaptations in rugby union players after a 4-week training program. Int J Sports Physiol Perform 14: 1205–1211, 2019. [DOI] [PubMed] [Google Scholar]
- 38.Weakley JJS, Wilson KM, Till K, et al. Visual feedback attenuates mean concentric barbell velocity loss and improves motivation, competitiveness, and perceived workload in male adolescent athletes: J Strength Cond Res 33: 2420–2425, 2019. [DOI] [PubMed] [Google Scholar]
- 39.Worsey M, Espinosa H, Shepherd J, Thiel D. Inertial sensors for performance analysis in combat sports: A systematic review. Sports 7: 28, 2019. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 40.Worsey MTO, Espinosa HG, Shepherd JB, Thiel DV. An evaluation of wearable inertial sensor configuration and supervised machine learning models for automatic punch classification in boxing. IoT 1: 360–381, 2020. [Google Scholar]
