Skip to main content
. 2023 Oct 27;4(1):e305. doi: 10.1002/deo2.305

TABLE 2b.

The stent patency periods and 1‐year stent dysfunction rates for the first endoscopic retrograde cholangiography.

Total IS PS
n = 48 n = 18 n = 30 p‐value
Median period of stent patency, days 196 369 154 0.01
Stent dysfunction factor
 Cases of stent occlusion within a year, n (%) 8 (44%) 14 (47%)
 One‐year stent occlusion rate, % 48% 65% 0.28
 Cases of acute cholangitis within a year, n (%) 2 (11%) 9 (30%)
 One‐year acute cholangitis rate, % 20% 43% 0.04
 Cases of stent dislocation within a year, n (%) 0 (0%) 10 (33%)
 One‐year stent dislocation rate, % 0% 43% 0.004

Abbreviations: IS, inside stent; PS, plastic stent.

The median periods of stent patency and 1‐year stent dysfunction rates were analyzed using the Kaplan‐Meier method (the log‐rank test).