Table 2.

TENS application characteristics.

Study Device Frequency Pulse Width Time Location of the Electrodes Types of Electrodes
[7] Dualpex 961 10 Hz 200 μs 20 min Trapezius muscle region (descending fibers) and submandibular region, bilaterally 2 pairs
(3.0 cm × 4.0 cm)
[1] Ibramed Neurodyn III Amethyst Line 15 Hz 250 μs 30 min On clean skin, positioned on the upper border, at the level of the hyoid bone, and on the lower border, below the cricoid cartilage, one centimeter apart from one another 1 pair
(3 cm × 5 cm)
[17] Quark Dualpex 961 10 Hz 200 μs 20 min Trapezius muscle and submandibular area 2 pairs
(3 cm × 5 cm)
[4] Dualpex 961 10 Hz 200 μs 20 min Trapezius region—upper fibers, bilaterally, and in the submandibular region 2 pairs
(5.0 cm × 5.0 cm)
[2] NEURODYN II 10 Hz 200 μs 20 min Lateral center of the larynx (thyroid cartilage) in the infrahyoid muscles, with 1 cm between them and on trapezius muscles Rectangular and composed of silicon (30 × 50 mm)
[18] Dualpex 961 10 Hz 200 μs 20 min Trapezius muscle (on the descending fiber) and on both sides of the submandibular region 2 pairs
(5.0 cm × 4.0 cm)
[8] ELPHA II 3000 100 Hz 50 μs 20 min Lateral center of the thyroid cartilage in the infrahyoid muscles and the motor point of the trapezius muscle on the descending fiber 2 pairs
(5 cm × 5 cm)