Abstract
Low-cost air quality monitors are growing in popularity among both researchers and community members to understand variability in pollutant concentrations. Several studies have produced calibration approaches for these sensors for ambient air. These calibrations have been shown to depend primarily on relative humidity, particle size distribution, and particle composition, which may be different in indoor environments. However, despite the fact that most people spend the majority of their time indoors, little is known about the accuracy of commonly used devices indoors. This stems from the fact that calibration data for sensors operating in indoor environments are rare. In this study, we sought to evaluate the accuracy of the raw data from PurpleAir fine particulate matter monitors and for published calibration approaches that vary in complexity, ranging from simply applying linear corrections to those requiring co-locating a filter sample for correction with a gravimetric concentration during a baseline visit. Our data includes PurpleAir devices that were co-located in each home with a gravimetric sample for 1-week periods (265 samples from 151 homes). Weekly-averaged gravimetric concentrations ranged between the limit of detection (3 μg/m3) and 330 μg/m3. We found a strong correlation between the PurpleAir monitor and the gravimetric concentration (R>0.91) using internal calibrations provided by the manufacturer. However, the PurpleAir data substantially overestimated indoor concentrations compared to the gravimetric concentration (mean bias error ≥ 23.6 μg/m3 using internal calibrations provided by the manufacturer). Calibrations based on ambient air data maintained high correlations (R ≥ 0.92) and substantially reduced bias (e.g. mean bias error = 10.1 μg/m3 using a US-wide calibration approach). Using a gravimetric sample from a baseline visit to calibrate data for later visits led to an improvement over the internal calibrations, but performed worse than the simpler calibration approaches based on ambient air pollution data. Furthermore, calibrations based on ambient air pollution data performed best when weekly-averaged concentrations did not exceed 30 μg/m3, likely because the majority of the data used to train these models were below this concentration.
Keywords: indoor air quality, low-cost sensors, fine particulate matter, calibration, exposure assessment, PurpleAir
1. Introduction
Although it is well established that American adults spend the majority of their time indoors, long-term monitoring of indoor concentrations has traditionally been infeasible. Filter-based sampling of for gravimetric analysis is considered the gold standard; however, the necessary pumps and size-selective sampling inlets, which can cost thousands of dollars, in addition to frequent maintenance requirements (e.g., replacing filters, calibrating flow rates) have made collection of indoor exposure data challenging. Recently, dramatic advances in lower-cost sensor technology have made indoor monitoring of exposures more feasible and increased acceptability to researchers and study participants. PurpleAir (Draper, UT) is one example of a consumer-grade monitor, containing Plantower PM sensors (Levy Zamora et al., 2019), that may be deployed indoors due to its small size and quiet operation. PurpleAir monitors are being deployed by community scientists and researchers in ambient air and indoor settings. As of 2020, over 5600 PurpleAir devices were reporting data to the company’s web-based map (more devices exist with data kept private by the device owners), with almost 18% of them deployed indoors (deSouza and Kinney, 2021).
Substantial effort has been made to evaluate and calibrate outdoor PurpleAir data with comparison against gravimetric measurements or state regulator monitors in the United States (Ardon-Dryer et al., 2020; Barkjohn et al., 2021; Holder et al., 2020; Magi et al., 2020; Malings et al., 2020; Tryner et al., 2020). Several studies have evaluated other low-cost monitors or their component sensors in laboratory settings or in the field (for example, see Giordano et al. (2021)). However, because reference-grade measurements of indoor concentrations needed for validation are rare, fewer studies have evaluated the accuracy of sensor estimated concentrations indoors (Sá et al., 2022). Sensors that rely on light scattering for measurement of particles, such as the one in the PurpleAir, are sensitive to relative humidity (and temperature to a lesser extent) as well as particle size, shape, and composition, which can vary between indoor and outdoor environments and between homes (e.g. Long et al., 2000). Furthermore, due to the presence of indoor sources like cooking or smoking, the range of concentrations encountered indoors is often much larger than commonly found in ambient air in the United States (McCormack et al., 2009; Mohammed et al., 2015). As such, the accuracy of calibrations developed for the correction of ambient data has not been established for indoor environments.
Existing studies evaluating lower-cost monitors indoors have often considered short-duration concentration variations due to various common household activities (e.g. cooking, smoking) either in a laboratory or single home or have deployment sensors for longer periods (weeks to months) in a single or small number of homes (Cowell et al., 2023; Hegde et al., 2020; Shen et al., 2021; Singer and Delp, 2018; Tryner et al., 2021; Zamora et al., 2020). In both study designs, a small number of sensors were typically evaluated (less than 10), and the limited evaluation settings means that the conditions captured are unlikely to represent the true variability that exists across a large number of homes. Some studies have relied on research-grade devices that are also based on light scattering without gravimetric correction for evaluations of sensors (e.g., Cowell et al., 2023; Park et al., 2023). Such studies can assess correlation between low-cost and higher-cost estimates of PM but are not well-suited to assess accuracy.
To address these knowledge gaps, we compiled data across six studies that measured weekly-averaged gravimetric concentrations and compared them against co-located concentration measurements from PurpleAir monitors deployed indoors in Baltimore, MD, USA. We then considered a set of four additional calibration approaches to evaluate if any approach improved monitor performance in indoor environments.
2. Methods
2.1. Study Populations
Indoor concentration data from the homes of participants enrolled in six studies in the Baltimore, MD metropolitan area were included (Table 1). Participants eligible for these studies included adults with chronic obstructive pulmonary disease (COPD), adults with or at risk for HIV, and children with asthma. Participants from various studies with different eligibility criteria were included in this analysis in an attempt to include households with different housing characteristics, smoking status, indoor activities, and ages of occupants. Below is a brief description of the studies included. In all studies, one-week measurements of gravimetric were made during a baseline visit and again 6 months later. Some of the studies additionally included a week of monitoring 3 months after the baseline visit. Many of the studies are in progress, and not all participants have repeated measurements yet. All studies were approved by the Johns Hopkins School of Medicine Institutional Review Board. The six included studies were:
Table 1.
Characteristics of participants in studies and visit schedule for each study.
| Study | Eligibility Age Range | Participant Disease Status | Smoking status of participant* | Visit Schedule | Number of Samples (Number of homes) |
|---|---|---|---|---|---|
| CURE COPD | 40+ | COPD | Former smoker | Baseline, 3 mo, 6 mo | 18 (9) |
| DREAM | 8–17 | Asthma | Non-smoker | Baseline, 3 mo, 6 mo | 22 (18) |
| HEAR COPD | 40+ | COPD | Current or former smoker | Baseline, 6 mo | 29 (20) |
| MOVE | 40+ | COPD | Current smoker | Baseline, 3 mo, 6 mo | 89 (47) |
| OMEGA | 40+ | COPD | Current or former smoker | Baseline, 3 mo, 6 mo | 22 (11) |
| SHIELD | 18+ | With or at risk for HIV | Current, former, or non-smoker | Baseline, 6 mo | 85 (61) |
There can be smoke exposure in the homes of non-smokers or former smokers from other household members.
Comparing Urban and Rural Effects of Poverty on COPD (CURE COPD) included non-smoking participants with moderate to severe chronic obstructive pulmonary disease (COPD). This study completed data collection in 2022.
The Home Environment and Hospitalization in COPD Study (HEAR COPD) is an ongoing study that includes participants who have been recently hospitalized for COPD and are current or former smokers.
Motivational Interviewing and Air Cleaners for Smokers with COPD (MOVE COPD) is an ongoing study that includes participants with moderate to severe COPD who are current smokers and allow smoking inside their home. After the baseline visit (prior to the intervention), participants were randomized to receive two air purifiers with either active HEPA filters or sham purifiers with the filters removed. Indoor measurements were repeated 3 and 6 months after the installation of the air purifiers.
The OMEGA Dietary Intervention – COPD Trial is an ongoing study that includes participants with moderate to severe COPD who are current or former smokers.
The Study of HIV Infection in the Etiology of Lung Disease (SHIELD) Air is an ongoing cohort of participants with or at risk for HIV, without regard for smoking status. However, the prevalence of smoking in the parent cohort is 85% (Raju et al., 2020).
Determining the Relationship between Environment, sleep, and AsthMa (DREAM) is an ongoing study that includes non-smoking child participants with moderate to severe asthma.
2.2. Indoor Air Monitoring
For all studies except DREAM, air monitoring equipment was deployed in the room the participant reported spending most of their time, commonly a bedroom, living room/dining room, or a den/office. Only two samples were deployed in a kitchen. For the DREAM study, the monitors were always deployed in the child’s bedroom. PurpleAir monitors, gravimetric sampling equipment, and air nicotine sampling equipment were placed in the same room. Participants were instructed not to move the equipment but were not asked to make any behavioral changes.
2.3. Gravimetric Concentrations
Filter samples for were collected using the Ultrasonic Personal Air Sampler (UPAS, Access Sensor Technologies, Fort Collins, CO) at 1 lpm for nominally a 1-week period. Samples were retained for this analysis that operated for at least 24 hours and up to 14 days. Some units operated continuously, and some units operated on a 50% duty cycle (30 seconds on, 30 seconds off) to reduce overloading of filters in homes where high concentrations were anticipated due to known smoking in the home. Concentrations measured with a 50% duty cycle have been shown to be highly correlated with concentrations measured without a duty cycle (Chiavassa et al., 2021). Each filter was adjusted for a batch-specific blank mass to account for filter handling. The limit of detection (LOD) for filter samples was set as three times the standard deviation of the blank filter mass (one blank filter was collected in every 10 samples for all studies). Values below the LOD were set to 1.6 μg/m3 or 3.1 μg/m3 (the LOD mass divided by two and turned into a concentration using the nominal sample time of one week and nominal flow rate of 1 lpm for devices operating at 100% or 50% duty cycle, respectively).
2.4. Air Nicotine Concentrations
Presence of indoor smoking was assessed by air nicotine concentrations from a passive sampler in the home for the duration of the one-week study visit (Hammond and Leaderer, 1987). Since many of the studies are ongoing, not all air nicotine samples have been analyzed at the time of this analysis. Results were dichotomized separating households having concentrations above or below the LOD (0.036 μg/m3 of nicotine).
2.5. PurpleAir Quality Control
The PurpleAir monitor logged concentrations every 1–2 minutes. The device contains two Plantower PMS5003 sensors (Nanchang Panteng Technology Co., Ltd., Nanchang, China). Following recommendations from the literature (Barkjohn et al., 2021), the data at each time point was checked to verify that these two sensors agreed within 40% or 5 μg/m3 (whichever is higher) and the measurement was invalidated if the sensors did not meet this criterion. The values from the two sensors were averaged for the final concentration measurement. The device also contains internal sensors for temperature and relative humidity (RH). The temperature and relative humidity data were used without further calibration.
The high temporal resolution PurpleAir measurements were averaged to a single arithmetic mean value for the week, matching the time period of the filter sample collection. Samples were retained for this analysis provided that the duration of the PurpleAir (both the and RH measurements needed for various calibration approaches, see below) was at least 75% of the duration of the filter sample.
2.6. Calibration Methods
Five calibration approaches were considered for the indoor environment.
Raw Data. The PurpleAir reports data using correction factors (CF) of both CF=1 and CF=“atm” provided by the Plantower manufacturer. We refer to the CF=1 internal Plantower calibration as the raw data.
- Relative Humidity (RH) Only. A previously published calibration was applied to account for known overestimation of PM concentrations by light scattering devices for RH>60% (Chakrabarti et al., 2004). At each time point, the sensor concentration was multiplied by the correction factor for RH>60%:
where RH is a fraction between 0 and 1. The CF was applied to the high temporal resolution data then the calibrated data was averaged over the length of the gravimetric sample collection. This approach has been commonly used for higher-cost devices also relying on light scattering for PM measurement (e.g. Delfino et al., 2006). - US-wide PurpleAir Calibration. A published calibration for ambient estimates from the PurpleAir was applied to the indoor data (Barkjohn et al., 2021):
where is the average of the two Plantower channels with the CF=1 manufacturer calibration applied and RH is in percent. The calibration was applied to the high temporal resolution data then the calibrated data was averaged over the length of the gravimetric sample collection. -
Baltimore Plantower Calibration. Data from an ambient air pollution monitoring network (Datta et al., 2020) was used to develop a statistical calibration for hourly concentrations of a monitor that used the Plantower A003 sensor (Buehler et al., 2021). Although this is not the same sensor as in the current PurpleAir devices, the sensor operation is very similar and includes CF=1 and CF=atm manufacturer calibrations. Data from a Beta Attenuation Monitor that was co-located at the Oldtown regulatory air monitoring site operated by the Maryland Department of the Environment between December 20, 2018 and July 31, 2019 was used to train this model. The model was evaluated against the Federal Reference Method manual gravimetric concentration (24-hour average; 1 in 6 days) at another co-located site in Essex, just outside the city of Baltimore. The PM data with the CF=atm calibration applied was first corrected for humidity and temperature using data from laboratory-based calibrations:Then a second calibration was applied:
where is temperature, is the sensor data with the laboratory-based humidity and temperature calibration applied, weekend is an indicator that takes a value of 1 on Saturday and Sunday, and daytime is an indicator that takes a value of 1 between 5 am and 7 pm or else the indicators take a value of zero. The slope coefficient is modeled not as a constant but as a constant plus linear combination of RH, T, weekend, and daytime. This allows interactions of all of these variables with the low-cost data to be included in the calibration model, accounting for bias that remained in the data after the application of the lab-based humidity and temperature correction. The calibration was applied to the high temporal resolution data then the calibrated data was averaged over the length of the gravimetric sample collection. -
Baseline Gravimetric Calibration. Gravimetric measurements from the baseline visit to a home were used to calibrate subsequent measurements in the same home, where:
Gravimetric is the weekly-averaged concentration measured from the UPAS and is the average of the two channels with the CF=1 manufacturer calibration applied averaged over the same duration. The CF was applied to the data at the next sampling event averaged over the length of the gravimetric sample collection. We note that because studies are ongoing and protocols are different between studies, not all homes have repeated measurements available for this analysis.
2.7. Statistical Methods
Several metrics for accuracy and precision were used to assess the five calibration approaches. Pearson’s correlation coefficient (R) reports values between −1 and 1 and larger values indicate stronger positive correlation. The root mean squared error (RMSE), mean bias error (MBE), and mean absolute error (MAE) were used to assess overall accuracy. For the gravimetric calibration approach, accuracy and precision were only evaluated for the repeated visits since the baseline data is used to produce the calibration factor (since the calibrated concentration perfectly matches the gravimetric concentration at the baseline visit). As a result, the sample size for this calibration approach is much smaller than for the other approaches. Sankey plots were used to visualize how participants from each study would be classified by quartile of exposure (across all measurements) by both the gravimetric concentration and PurpleAir data.
Linear regressions were fit between the gravimetric concentrations and the different calibration approaches where the intercept was set to be zero. We evaluated accuracy over the range of measured concentrations using Bland-Altman plots. Since samples collected in the same home were at least 3 months apart, data were treated as independent in the statistical analyses. Baseline samples only were considered in a sensitivity analysis for all calibration approaches except the Baseline Gravimetric Calibration because in that case the baseline data is used only to calibrate future samples in the same home. Finally, we investigated whether there were differences in the slope between the gravimetric and calibrated PurpleAir data for different groups of samples by study, smoking status, or type of room in which the monitors were located using an analysis of covariance (intercepts not forced to zero).
3. Results
3.1. Indoor concentrations
Concentrations in Baltimore City homes across all studies generally exceeded the median weekly-averaged ambient concentrations, which was 7 μg/m3 in 2021 at the Oldtown monitoring site in Baltimore City (Environmental Protection Agency, 2021). Including all studies, the median gravimetric mass concentration was 26 μg/m3 when averaged over the visit duration (nominally 7 days; range 1–14 days). Values were approximately log-normally distributed with the lowest value below the LOD and the highest concentration exceeding 330 μg/m3. Concentrations measured for the six studies separately and for all five calibration approaches are shown in the Supplemental Information (Table S1). The median mass concentration was highest for households enrolled in the MOVE study and the lowest median concentration was observed for households enrolled in the CURE COPD study. This result is not surprising as MOVE only enrolled households with participants who smoke indoors and the CURE COPD study only included former smokers. The PurpleAir raw data was biased substantially higher compared to the gravimetric mass concentration (gold standard) with median concentrations from all studies estimated to be twice as high (53 μg/m3). This overestimation has been previously shown for ambient concentrations (e.g., Barkjohn et al., 2021).
3.2. Accuracy of Calibration Methods
The raw PurpleAir concentrations, PurpleAir concentrations calculated using the US-wide ambient calibration and the Baltimore ambient calibration, were compared against the gravimetric concentrations (Figure 1). The raw concentrations substantially overestimate the true concentrations (slope of linear regression [m] = 2.08). Both the US-wide and Baltimore ambient calibration approaches result in concentrations in much better agreement with the gravimetric concentrations; however, the US-wide calibration approach tends to overestimate concentrations (m = 1.12), while the Baltimore approach tends to underestimate concentrations (m = 0.75). The US-wide and Baltimore ambient calibration approaches perform similarly for concentrations less than ~20 μg/m3 (Figure S1 shows only concentrations below 100 μg/m3), such that, in this range, these calibration approaches are close to the gravimetric concentration while the gap widens at higher concentrations. It is not surprising that these approaches work best for lower concentrations since the majority of ambient concentrations measured in the United States fall in this range with the 90th percentile of daily concentrations in the United States in 2021 at 31.8 μg/m3 (Environmental Protection Agency, 2022).
Figure 1.
Comparison of weekly-averaged raw PurpleAir data (CF=1; green) and the US-wide (blue) and Baltimore (red) ambient air calibration approaches against gravimetric mass concentrations. Lines of the corresponding colors are best linear fits to the raw or calibrated sensor data against the gravimetric data with a forced zero intercept. The thick black line is the one-to-one line.
The RMSE, MBE, MAE, and R values for the raw data and each calibration approach are included in Table 2 for all studies combined and restricted to samples where the gravimetric concentration was below 30 μg/m3. The RMSE when using the raw data or the other internal calibrations (i.e., CF=1, CF=atm) is very large, over 39 μg/m3. For indoor data, the RH Only calibration performs nearly identically to the raw data (CF=1) because few indoor measurements of RH were above 60% and so there is no alteration of the data (i.e., affecting less than 0.1% of the 1–2 minute PurpleAir measurements). It is important to note that the temperature and relative humidity sensor in the PurpleAir device captures the conditions inside the device (i.e. at somewhat warmer temperatures and correspondingly lower relative humidity), not the room temperature and humidity conditions. This may contribute to the low impact of the RH Only calibration. The RMSE for the US-Wide and Baltimore ambient calibration approaches are nearly identical when all data is considered (~22 μg/m3), but the RMSE for the Baltimore ambient calibration is about 40% lower when only considering weekly-averaged concentrations below 30 μg/m3. The RMSE for the baseline gravimetric calibration was between the raw data and the ambient calibrations. It is interesting that this home-specific calibration does not perform better than the ambient calibrations, particularly since this is the most labor-intensive calibration approach. Since all follow up visits are 3 and/or 6 months after the baseline visit, we cannot assess whether such an approach would be more successful if all monitoring was completed in a single season.
Table 2.
Accuracy Metrics for different calibration approaches.
| All Studies Combined | Concentration < 30 μg/m3 | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Calibration Method | N | RMSE (μg/m3) | MBE (μg/m3) | MAE (μg/m3) | R | N | RMSE (μg/m3) | MBE (μg/m3) | MAE (μg/m3) | R |
| Raw (CF=1) | 265 | 78 | 50.7 | 51.1 | 0.93 | 150 | 29.4 | 17 | 17.6 | 0.68 |
| Internal calibration (CF=atm) | 265 | 39.8 | 23.6 | 24.9 | 0.91 | 150 | 18 | 9.8 | 10.7 | 0.7 |
| RH Only calibration | 265 | 78 | 50.7 | 51.1 | 0.93 | 150 | 29.4 | 17 | 17.6 | 0.68 |
| US-Wide calibration | 265 | 21.9 | 10.1 | 13.6 | 0.93 | 150 | 12.7 | 5.7 | 7 | 0.68 |
| Baltimore-based calibration | 265 | 21.8 | 4.9 | 11.2 | 0.92 | 150 | 7.7 | 2.2 | 4.6 | 0.7 |
| Baseline gravimetric calibration | 96 | 46.3 | 17.5 | 28.7 | 0.62 | 57 | 35.7 | 17.2 | 19.8 | 0.51 |
Bland Altman plots for the two ambient calibrations, which are the best performing according to their RMSEs, are shown in the Supplemental Information (Figure S2). Although the absolute value of the mean bias for the Baltimore ambient calibration is smaller (−4.9 μg/m3) than the US-Wide calibration (10.1 μg/m3), there is evidence that the Baltimore calibration performs well at lower concentrations, but underestimates concentrations as concentrations increase. The overestimation trend for the US-Wide calibration is clear for concentrations between around 50–125 μg/m3 but is less pronounced for the highest concentrations.
The Pearson’s correlation (R) values between the different approaches are very similar, except for the gravimetric calibration approach, which is substantially poorer performing, although the sample size is also substantially smaller (i.e., 96 samples versus 265 for other approaches).
Since the US-Wide calibration performed well and could be easily applied by other users of PurpleAir devices, we evaluated whether there were differences in the slope between the gravimetric concentration and the US-Wide calibration approach for different groups of samples. There was no evidence of differences in the slopes between studies. When comparing samples collected in living spaces (i.e. living rooms, dining rooms, dens, or offices; N=100) to samples collected in bedrooms (N=111), statistically different slopes were observed. Samples collected in living spaces tended to be slightly underestimated (m=0.98) and samples collected in bedrooms tended to be overestimated (m=1.13). Comparing homes with (N=65) and without (N=98) detectible air nicotine, a statistically significant difference in slope was observed (m = 0.83 for homes without detectible air nicotine versus m = 1.01 for homes with detectible air nicotine). For 102 samples the air nicotine data was unavailable. Only three samples without detectible air nicotine had gravimetric concentrations greater than 75 μg/m3 compared to 23 samples with detectible air nicotine. When considering only samples with gravimetric concentrations lower than 75 μg/m3, there was no significant difference in the slope between homes with and without detectible air nicotine. These results may suggest that a difference in calibration performance is present for homes with relatively high indoor concentrations due to sources other than cigarette smoking, however, it should be noted that the sample size for this comparison is very small (N=3 homes with gravimetric mass concentration greater than 75 μg/m3 without detectible air nicotine). Finally, we evaluated whether the performance of the baseline gravimetric calibration varied by study, but no statistically significant differences in the slopes were observed.
As a sensitivity analysis, we calculated the accuracy metrics only for samples collected during baseline visits, which reduces the sample sizes by approximately half (Table S2). For baseline samples, RMSE, MBE, and MAE increased 6–61% over all calibration approaches compared to all samples, but the R values were very similar. Similarly, as with all samples, accuracy among baseline samples was greatly improved by applying either the US-Wide or Baltimore-based ambient calibrations. Finally, there are two updates to the US-Wide calibration for cases when high ambient concentrations are present due to wildfire smoke (Johnson Barkjohn et al., 2021). We evaluated these two approaches but found that they performed worse than the standard US-Wide calibration, even for homes with high weekly mean concentrations. Accuracy metrics for these calibrations and the equations used are included in Table S3.
3.3. Exposure Misclassification
For some epidemiologic analysis, it may be useful to know whether individuals would be assigned to appropriate exposure groups (e.g., quartiles of exposure) when a lower accuracy, but more feasible exposure assessment strategy is used, such as PurpleAir monitors. A Sankey plot was used to visualize this in Figure 2. Participants from the various studies were generally spread among the four quartiles of exposure based on the gravimetric concentration. Given the strong correlation between the gravimetric concentrations and even the raw (CF=1) PurpleAir data without any extra calibration, the majority of participants were assigned to the correct quartile of exposure (76%). Only a small number of participants (2%) moved quartiles between the raw and calibrated data using the US-Wide ambient calibration (only 9% moved quartiles between the raw and the Baltimore-based ambient calibration; not shown).
Figure 2:
Sankey plot showing partitioning of participants from all studies to quartiles of exposure by gravimetric concentration and PurpleAir estimates (Raw and Calibrated using the Baltimore ambient calibration). Gravimetric concentration quartiles were split as: Quantile 1: LOD to 10, Quantile 2: 10 to 25, Quantile 3: 26 to 55, and Quantile 4: 55 to 330 μg/m3.
4. Discussion
Given the large number of homes included with very different study populations (e.g. elderly adults, homes with young children, etc.), this study provides a more comprehensive assessment of the performance of consumer-grade monitors to capture concentrations in homes than has been reported in the literature to date. Tryner et al. (2021) evaluated a custom-built monitor that contained the same sensor as the PurpleAir for 1-week duration in a single home. The region was impacted by wildfire smoke during this assessment. Nine monitors and a tapered element oscillating microbalance (TEOM 1405, Fisher Scientific, Waltham, MA, USA) as a reference device were placed in the home and measured hourly-averaged concentrations ranging from approximately 0–70 μg/m3 (daily averages not reported), a much lower range of conditions than considered in this work. Sensor concentrations were corrected using the US-Wide calibration as daily averages and the RMSE was 4.5 μg/m3. Similarly, Zamora et al. (2020) reported on the accuracy of two AirThinx monitors (AirThinx, Inc., Philadelphia, PA) that also contain the same sensor as the PurpleAir in a single home. For one week each month during a one-year period, the monitors were compared to a gravimetrically corrected light-scattering nephelometer (pDR-1200; Thermo Scientific Corp., Waltham, Mass.). Those authors reported an RMSE of 2.2 μg/m3 of 1-minute averaged data over 56 days of sampling using a gravimetric correction factor approach. The reported RMSE by those authors is lower than found here, even when we restricted to weekly-averaged concentrations less than 30 μg/m3. The higher RMSEs found in this larger sample size suggest that variability in indoor sources contributes to variability in sensor response and that evaluations with small sample numbers may overestimate sensor performance. For example, the difference in slopes between the PurpleAir and gravimetric sample when comparing living spaces and bedrooms may reflect the fact that living spaces are more likely to be in closer proximity to kitchens. Many of the participants in these studies live in rowhomes, which are narrow, multistory dwellings that are often joined by side walls. Living spaces are more likely to be on the main floor with the kitchen and bedrooms being more likely on upper floors of the home, away from the PM emissions from cooking.
Strengths of this study include the large number of homes and wide range of weekly-averaged concentrations that were measured across all seasons. Since the range of concentrations observed in this study are larger than reported in many previous studies evaluating sensors both indoors and outdoors, normalized RMSE and MAE were also included in Table S3. The study included both homes with cigarette smoking and without. Limitations are that only homes in the Baltimore metropolitan area were included and home size, room size and floor of the home where monitoring was completed were not recorded. Inside homes the relative humidity conditions were generally less than 60% (as measured inside the PurpleAir), in line with recommendations for indoor air quality by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE, 2016). It is not clear whether there are differences in the accuracy of the calibrations when high concentrations are encountered due to sources other than smoking. We also have not evaluated the accuracy of shorter duration peak exposures. Finally, the transferability of the Baltimore-based ambient calibration to other regions of the U.S. is unclear. Future work should consider whether these calibration approaches have similar accuracy in other geographic areas, the accuracy of peak exposures, and whether there are degradations in performance when PurpleAir devices are installed for long periods of time in indoor environments (months to years). Evaluation of PurpleAir performance in outdoor environments has shown stable error in the corrected measurements for durations up to 3 years (deSouza et al., 2023). That work showed that degradation of the sensors was most pronounced in hot and humid environments, but it is possible this degradation could also occur faster in indoor environments due to the higher concentrations often encountered indoors than in ambient air.
5. Conclusion
This study sought to evaluate how various calibration approaches could be used to estimate indoor exposure to using a PurpleAir monitor when these devices are evaluated in a large number of homes and a wide range of concentrations. Strong correlation was observed between gravimetric concentrations (the gold standard) and both raw and calibrated PurpleAir data. Thus, the relatively inexpensive approach using this monitor can accurately assign households to exposure quartiles. Raw estimates were biased substantially high, but existing calibrations were able to reduce these biases substantially. The Baltimore-specific calibration resulted in the lowest RMSE of calibration approaches considered, particularly for lower concentration ranges (about 40% lower for mass concentrations <30 μg/m3). However, these results suggest that the existing US-Wide calibration can be easily applied to indoor data by researchers and community members resulting in substantial improvements in data accuracy compared to the internal calibration. However, RMSE values were higher than have been previously reported in the literature, pointing to the importance of evaluating performance of consumer grade devices in a large number of real-world homes. PurpleAir monitors are relatively low-cost, easy to deploy, and can send data through Wi-Fi to a cloud server enabling remote data collection. This, and similar devices, show promise to enable long-term (weeks to months) assessment of PM exposures in home environments and for community engaged research.
Supplementary Material
Figure S1: Comparison of weekly-averaged raw PurpleAir data (CF=1; green) and the US-wide (blue) and Baltimore (red) ambient air calibration approaches against gravimetric mass concentrations for values under 100 μg/m3. Lines of the corresponding colors are best linear fits to the raw or calibrated sensor data against the gravimetric data with a forced zero intercept. The thick black line is the one-to-one line.
Figure S2: Bland-Altman plots show (A) the difference between the US-Wide and gravimetric concentration or (B) the difference between the Baltimore calibration and the gravimetric concentration plotted against the mean concentration. The mean bias is shown as a solid line. The upper and lower limits of agreement at the 95th percentile confidence interval are shown as dashed lines. The upper limits of agreement for the US-Wide and Baltimore ambient calibrations are 48.3 and 36.9 μg/m3, respectively. The lower limits of agreement for the US-Wide and Baltimore ambient calibrations are −28.1 and −46.7 μg/m3, respectively.
Highlights.
Calibration of PM sensors indoors are needed for long-term exposure assessment
PurpleAir monitor and gravimetric measurements of PM are highly correlated in homes
Calibrations based on ambient increase the accuracy of the PurpleAir indoors
PurpleAir monitors show promise for longer-term assessment of PM exposures in homes
Acknowledgements
This work was supported by the National Institute of Environmental Health Sciences (NIEHS) under grant numbers R01ES029512, R01ES029999, and P2CES033415; the National Institute on Minority Health and Health Disparities (NIMHD) under grant number P50MD010431; and the National Heart Lung and Blood Institute (NHLBI) under grant numbers R01HL158615, R01HL152419, and R01HL154860. AD and KK were partially supported by NIEHS grant R01ES033739. MLZ is supported by NIEHS under award number R00ES029116. This publication was also developed under Assistance Agreement no. RD835871 awarded by the U.S. Environmental Protection Agency to Yale University and R83451001 to Johns Hopkins University. It has not been formally reviewed by the Environmental Protection Agency (EPA). The views expressed in this document are solely those of the authors and do not necessarily reflect those of the Agency. The EPA does not endorse any products or commercial services mentioned in this publication. CB is supported by the National Science Foundation Graduate Research Fellowship Program under grant no. DGE1752134. Any opinions, findings, conclusions, or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation.
Footnotes
Declaration of interests
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.
Publisher's Disclaimer: This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.
References
- 1.ANSI/ASHRAE, 2016. Ventilation for Acceptable Indoor Air Quality, Addenda, 62.12016, Atlanta, GA. [Google Scholar]
- 2.Ardon-Dryer K, Dryer Y, Williams JN, Moghimi N, 2020. Measurements of PM2.5 with PurpleAir under atmospheric conditions. Atmos. Meas. Tech 13, 5441–5458. [Google Scholar]
- 3.Barkjohn KK, Gantt B, Clements AL, 2021. Development and application of a United States-wide correction for PM2.5 data collected with the PurpleAir sensor. Atmos. Meas. Tech 14, 4617–4637. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 4.Buehler C, Xiong F, Zamora ML, Skog KM, Kohrman-Glaser J, Colton S, McNamara M, Ryan K, Redlich C, Bartos M, Wong B, Kerkez B, Koehler K, Gentner DR, 2021. Stationary and portable multipollutant monitors for high-spatiotemporal-resolution air quality studies including online calibration. Atmos. Meas. Tech 14, 995–1013. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 5.Chakrabarti B, Fine PM, Delfino R, Sioutas C, 2004. Performance evaluation of the active-flow personal DataRAM PM2.5 mass monitor (Thermo Anderson pDR-1200) designed for continuous personal exposure measurements. Atmospheric Environment 38, 3329–3340. [Google Scholar]
- 6.Chiavassa P, Gandino F, Giusto E, 2021. An investigation on duty-cycle for particulate matter monitoring with light-scattering sensors, 2021 6th International Conference on Smart and Sustainable Technologies (SpliTech), pp. 1–6. [Google Scholar]
- 7.Cowell N, Chapman L, Bloss W, Srivastava D, Bartington S, Singh A, 2023. Particulate matter in a lockdown home: evaluation, calibration, results and health risk from an IoT enabled low-cost sensor network for residential air quality monitoring. Environmental Science: Atmospheres 3, 65–84. [Google Scholar]
- 8.Datta A, Saha A, Zamora ML, Buehler C, Hao L, Xiong F, Gentner DR, Koehler K, 2020. Statistical field calibration of a low-cost PM2.5 monitoring network in Baltimore. Atmospheric Environment 242, 117761. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 9.Delfino RJ, Staimer N, Gillen D, Tjoa T, Sioutas C, Fung K, George SC, Kleinman MT, 2006. Personal and ambient air pollution is associated with increased exhaled nitric oxide in children with asthma. Environ Health Perspect 114, 1736–1743. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 10.deSouza P, Barkjohn K, Clements A, Lee J, Kahn R, Crawford B, Kinney P, 2023. An analysis of degradation in low-cost particulate matter sensors. Environmental Science: Atmospheres 3, 521–536. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 11.deSouza P, Kinney PL, 2021. On the distribution of low-cost PM2.5 sensors in the US: demographic and air quality associations. Journal of Exposure Science & Environmental Epidemiology 31, 514–524. [DOI] [PubMed] [Google Scholar]
- 12.Environmental Protection Agency, 2021. Annual Summary Data. [Google Scholar]
- 13.Environmental Protection Agency, 2022. Our Nation’s Air Trends through 2021. USEPA. [Google Scholar]
- 14.Giordano MR, Malings C, Pandis SN, Presto AA, McNeill VF, Westervelt DM, Beekmann M, Subramanian R, 2021. From low-cost sensors to high-quality data: A summary of challenges and best practices for effectively calibrating low-cost particulate matter mass sensors. Journal of Aerosol Science 158, 105833. [Google Scholar]
- 15.Hammond SK, Leaderer BP, 1987. A Diffusion Monitor to Measure Exposure to Passive Smoking. Environmental Science & Technology 21, 494–497. [DOI] [PubMed] [Google Scholar]
- 16.Hegde S, Min KT, Moore J, Lundrigan P, Patwari N, Collingwood S, Balch A, Kelly KE, 2020. Indoor Household Particulate Matter Measurements Using a Network of Low-cost Sensors. Aerosol and Air Quality Research 20, 381–394. [Google Scholar]
- 17.Holder AL, Mebust AK, Maghran LA, McGown MR, Stewart KE, Vallano DM, Elleman RA, Baker KR, 2020. Field Evaluation of Low-Cost Particulate Matter Sensors for Measuring Wildfire Smoke, Sensors. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 18.Johnson Barkjohn K, Holder A, Clements A, Frederick S, Evans R, 2021. Sensor data cleaning and correction: Application on the AirNow Fire and Smoke Map, American Association for Aerosol Research Conference, Albuquerque, NM. [Google Scholar]
- 19.Levy Zamora M, Xiong F, Gentner D, Kerkez B, Kohrman-Glaser J, Koehler K, 2019. Field and Laboratory Evaluations of the Low-Cost Plantower Particulate Matter Sensor. Environmental Science & Technology 53, 838–849. [DOI] [PubMed] [Google Scholar]
- 20.Long CM, Suh HH, Koutrakis P, 2000. Characterization of Indoor Particle Sources Using Continuous Mass and Size Monitors. Journal of the Air & Waste Management Association 50, 1236–1250. [DOI] [PubMed] [Google Scholar]
- 21.Magi BI, Cupini C, Francis J, Green M, Hauser C, 2020. Evaluation of PM2.5 measured in an urban setting using a low-cost optical particle counter and a Federal Equivalent Method Beta Attenuation Monitor. Aerosol Science and Technology 54, 147–159. [Google Scholar]
- 22.Malings C, Tanzer R, Hauryliuk A, Saha PK, Robinson AL, Presto AA, Subramanian R, 2020. Fine particle mass monitoring with low-cost sensors: Corrections and long-term performance evaluation. Aerosol Science and Technology 54, 160–174. [Google Scholar]
- 23.McCormack MC, Breysse PN, Matsui EC, Hansel NN, Williams D, CurtinBrosnan J, Eggleston P, Diette GB, Center for Childhood Asthma in the Urban E, 2009. In-home particle concentrations and childhood asthma morbidity. Environ Health Perspect 117, 294–298. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 24.Mohammed MOA, Song W-W, Ma W-L, Li W-L, Ambuchi JJ, Thabit M, Li Y-F, 2015. Trends in indoor–outdoor PM2.5 research: A systematic review of studies conducted during the last decade (2003–2013). Atmospheric Pollution Research 6, 893–903. [Google Scholar]
- 25.Park S, Lee S, Yeo M, Rim D, 2023. Field and laboratory evaluation of PurpleAir low-cost aerosol sensors in monitoring indoor airborne particles. Building and Environment 234, 110127. [Google Scholar]
- 26.Raju S, McCormack MC, Drummond MB, Ramamurthi HC, Merlo CA, Wise RA, Mehta SH, Brown RH, Kirk GD, 2020. Association of Lung Function With HIV-Related Quality of Life and Health Care Utilization in a High-Risk Cohort. JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES 85, 219–226. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 27.Sá JP, Alvim-Ferraz MCM, Martins FG, Sousa SIV, 2022. Application of the low-cost sensing technology for indoor air quality monitoring: A review. Environmental Technology & Innovation 28, 102551. [Google Scholar]
- 28.Shen H, Hou W, Zhu Y, Zheng S, Ainiwaer S, Shen G, Chen Y, Cheng H, Hu J, Wan Y, Tao S, 2021. Temporal and spatial variation of PM2.5 in indoor air monitored by low-cost sensors. Science of The Total Environment 770, 145304. [DOI] [PubMed] [Google Scholar]
- 29.Singer BC, Delp WW, 2018. Response of consumer and research grade indoor air quality monitors to residential sources of fine particles. Indoor Air 28, 624–639. [DOI] [PubMed] [Google Scholar]
- 30.Tryner J, L’Orange C, Mehaffy J, Miller-Lionberg D, Hofstetter JC, Wilson A, Volckens J, 2020. Laboratory evaluation of low-cost PurpleAir PM monitors and in-field correction using co-located portable filter samplers. Atmospheric Environment 220, 117067. [Google Scholar]
- 31.Tryner J, Phillips M, Quinn C, Neymark G, Wilson A, Jathar SH, Carter E, Volckens J, 2021. Design and testing of a low-cost sensor and sampling platform for indoor air quality. Building and Environment 206, 108398. [DOI] [PMC free article] [PubMed] [Google Scholar]
- 32.Zamora ML, Rice J, Koehler K, 2020. One year evaluation of three low-cost PM2.5 monitors. Atmospheric Environment 235, 117615. [DOI] [PMC free article] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.
Supplementary Materials
Figure S1: Comparison of weekly-averaged raw PurpleAir data (CF=1; green) and the US-wide (blue) and Baltimore (red) ambient air calibration approaches against gravimetric mass concentrations for values under 100 μg/m3. Lines of the corresponding colors are best linear fits to the raw or calibrated sensor data against the gravimetric data with a forced zero intercept. The thick black line is the one-to-one line.
Figure S2: Bland-Altman plots show (A) the difference between the US-Wide and gravimetric concentration or (B) the difference between the Baltimore calibration and the gravimetric concentration plotted against the mean concentration. The mean bias is shown as a solid line. The upper and lower limits of agreement at the 95th percentile confidence interval are shown as dashed lines. The upper limits of agreement for the US-Wide and Baltimore ambient calibrations are 48.3 and 36.9 μg/m3, respectively. The lower limits of agreement for the US-Wide and Baltimore ambient calibrations are −28.1 and −46.7 μg/m3, respectively.


