Skip to main content
. 2023 Sep 26;11(10):814. doi: 10.3390/toxics11100814

Table 2.

Forecasting dose based on distance and time after injection in exponential regression equation. The relationship between distance at 30, 60, 100, and 200 cm at 0 h (injection time), 1.5 h (waiting time), and 3 h (scanning/discharge time) at left lateral, right lateral, anterior, and posterior orientations.

Patient
Position
Distance
(cm)
Time (h)
0 1.5 3
(Exponential
Regression)
Dose * (μSv/h)
Fold Change
from 0 h
at 30 cm
(Exponential
Regression)
Dose * (μSv/h)
Fold Change
from 1.5 h
at 30 cm
(Exponential
Regression)
Dose * (μSv/h)
Fold Change
from 3 h
at 30 cm
Left lateral 30 12.27 7.37 4.23
60 9.41 −0.23 5.66 −0.23 3.30 −0.22
100 6.61 −0.46 3.97 −0.46 2.36 −0.44
200 2.73 −0.78 1.64 −0.78 1.03 −0.76
Right lateral 30 12.14 6.97 4.08
60 9.23 −0.24 5.36 −0.23 3.15 −0.23
100 6.40 −0.47 3.78 −0.46 2.23 −0.45
200 2.57 −0.79 1.58 −0.77 0.94 −0.77
Anterior 30 18.67 11.17 6.25
60 13.77 −0.26 8.24 −0.26 4.71 −0.25
100 9.17 −0.51 5.49 −0.51 3.23 −0.48
200 3.32 −0.82 1.99 −0.82 1.25 −0.80
Posterior 30 19.80 11.87 6.75
60 14.51 −0.27 8.75 −0.26 5.06 −0.25
100 9.59 −0.52 5.83 −0.51 3.44 −0.49
200 3.41 −0.83 2.11 −0.82 1.31 −0.81

* The (exponential regression) dose was calculated using the exponential regression equations from Figure 5 shown in y=a×bx, where y is the mean dose rate (μSv/h) and x is the distance from the patient (cm).