Table 2.
Patient Position |
Distance (cm) |
Time (h) | |||||
---|---|---|---|---|---|---|---|
0 | 1.5 | 3 | |||||
(Exponential Regression) Dose * (μSv/h) |
Fold Change from 0 h at 30 cm |
(Exponential Regression) Dose * (μSv/h) |
Fold Change from 1.5 h at 30 cm |
(Exponential Regression) Dose * (μSv/h) |
Fold Change from 3 h at 30 cm |
||
Left lateral | 30 | 12.27 | 7.37 | 4.23 | |||
60 | 9.41 | −0.23 | 5.66 | −0.23 | 3.30 | −0.22 | |
100 | 6.61 | −0.46 | 3.97 | −0.46 | 2.36 | −0.44 | |
200 | 2.73 | −0.78 | 1.64 | −0.78 | 1.03 | −0.76 | |
Right lateral | 30 | 12.14 | 6.97 | 4.08 | |||
60 | 9.23 | −0.24 | 5.36 | −0.23 | 3.15 | −0.23 | |
100 | 6.40 | −0.47 | 3.78 | −0.46 | 2.23 | −0.45 | |
200 | 2.57 | −0.79 | 1.58 | −0.77 | 0.94 | −0.77 | |
Anterior | 30 | 18.67 | 11.17 | 6.25 | |||
60 | 13.77 | −0.26 | 8.24 | −0.26 | 4.71 | −0.25 | |
100 | 9.17 | −0.51 | 5.49 | −0.51 | 3.23 | −0.48 | |
200 | 3.32 | −0.82 | 1.99 | −0.82 | 1.25 | −0.80 | |
Posterior | 30 | 19.80 | 11.87 | 6.75 | |||
60 | 14.51 | −0.27 | 8.75 | −0.26 | 5.06 | −0.25 | |
100 | 9.59 | −0.52 | 5.83 | −0.51 | 3.44 | −0.49 | |
200 | 3.41 | −0.83 | 2.11 | −0.82 | 1.31 | −0.81 |
* The (exponential regression) dose was calculated using the exponential regression equations from Figure 5 shown in , where y is the mean dose rate (μSv/h) and x is the distance from the patient (cm).