Skip to main content
. 2023 Oct 12;23(20):8423. doi: 10.3390/s23208423

Table 3.

Bland–Altman analyses values for the HRV and EDA parameters reported in Figure 3 and Figure 4. Bold types stand for statistical significance according to the aforementioned criterion and the current p-value. Upper and lower LOAs are reported as bias ± SD. Abbreviations: CI = Confidence Interval.

Condition Bias Bias CI 95% p-Value (Bias) Upper LOA Lower LOA
Mean IBI
Baseline 1.70 1.53 0.03 6.89 −3.49
Video Clip 1.07 3.16 0.48 11.80 −9.66
NR Driving 0.52 3.15 0.73 11.23 −10.19
RMSSD
Baseline −1.07 4.19 0.59 13.14 −15.29
Video Clip 3.18 8.88 0.45 33.34 −26.97
NR Driving 8.19 6.92 0.02 31.67 −15.28
HRV LF Spectrum
Baseline 5.42 5.03 0.04 22.49 −11.65
Video Clip 1.29 5.85 0.64 21.15 −18.58
NR Driving −0.79 4.56 0.71 14.68 −16.25
Mean EDA Tonic
Baseline 0.15 0.70 0.64 2.54 −2.23
Video Clip −0.58 0.26 <0.001 0.30 −1.46
NR Driving 0.72 0.98 0.12 2.80 −1.35