Skip to main content
. 2022 May 24;18(8):1323–1329. doi: 10.1177/15589447221092058

Table 2.

Radiographic Computed Tomography Findings.

Variable Flexor tenosynovitis group* (n = 35) Finger cellulitis group* (n = 35) P value
Radiologist reads fluid in tendon sheath (Y) 18 (51%) 0 (0%) <.0001
Study observer notes fluid in tendon sheath (Y) 34 (97%) 0 (0%) <.0001
Diameter of tendon sheath in coronal plane (mm) 11.4 ± 2.5 9.62 ± 1.5 <.001
Diameter of tendon sheath in sagittal plane (mm) 9.2 ± 2.8 6.2 ± 1.0 <.0001
Diameter of tendon in coronal plane (mm) 7.6 ± 1.8 8.3 ± 1.4 .09
Diameter of tendon in sagittal plane (mm) 5.5 ± 1.8 5.2 ± 0.9 .33
Ratio of tendon sheath diameter: tendon diameter in coronal plane (CR) 1.5 ± 0.2 1.2 ± 0.08 <.0001
Ratio of tendon sheath diameter: tendon diameter in sagittal plane (SR) 1.7 ± 0.3 1.2 ± 0.09 <.0001

Note. CR = coronal plane; SR = sagittal plane.

*

Values are expressed as means ± standard deviations or as absolute values with percentages in parentheses.