Skip to main content
. 2023 Nov 1;20(208):20230472. doi: 10.1098/rsif.2023.0472

Table 2.

Parameters employed in the FE element simulations of abdominal aortic aneurysms.

geometry and loading
parameter description early AAA late AAA refs.
R0 (mm) radius of healthy aortic wall ____________ 5.61 _____________ [52]
T0 (mm) thickness of aortic wall ____________ 1.46 _____________ [52]
dan (mm) maximum diameter of AAA in vivo ___________ 45-55-65 ___________
2R0,an (mm) initial diameter of the AAA (for each dan) 36.4-45.0-53.6 39.7-49.0-56.6
f1 (−) geometric parameter _____________ 4.0 _____________
c1 (−) geometric parameter _____________ 0.5 _____________
λax (−) axial prestretch in vivo ____________ 1.184 ____________
p (mmHg) internal pressure ____________ 120.0 ____________
material parameters
parameter description early AAA [40] late AAA [40] ILT [45]
μA (kPa) shear modulus of matrix 0.59 3.78
μI (kPa) stress-like parameter for ILT 9.26
b (−) non-dimensional parameter for ILT 1.62
k1 (kPa) shear modulus of fibres 1.30 8.96
k2 (−) exponential parameter of fibres 47.51 636.29
κip (−) in-plane fibre dispersion 0.242 0.224
κop (−) out-of-plane fibre dispersion 0.433 0.402
α (deg) in-plane fibre anglea 6.55 22.90

aWith respect to the local circumferential direction.