Skip to main content
. 2023 Oct 25;623(7985):48–57. doi: 10.1038/s41586-023-06558-8

Extended Data Fig. 7. Experimentally measured latency for weight switching by SRAM in ACCEL.

Extended Data Fig. 7

a–d, Experimentally measured time of weight switching of SRAM in all four situations: from 1 to 1 (a), from −1 to 1 (b), from 1 to −1 (c) and from −1 to −1 (d). e–h, Calculated time of weight switching by SRAM with parameters from the foundry with post-simulation in all four situations: from 1 to 1 (e), from −1 to 1 (f), from 1 to −1 (g) and from −1 to −1 (h).

Source Data