Table 1. Specifications of Solarex MSX60 60 W PV panel.
Parameter | Value |
---|---|
Open circuit voltage (VOC) | 64.2 V |
Short circuit current (Isc) | 5.96 A |
Voltage at max power (Vm) | 54.7 V |
Current at max power (Im) | 5.58 A |
Maximum power (Pm) | 305.226 W |
Temperature coefficient of open circuit voltage (β) | -(0.27269) mV/°C |
Temperature coefficient of short circuit current (α) | (0.061745±0.015) %/°C |
Temperature coefficient of power (μ) | -(0.512±0.05) %/°C |
Light-generated current (IL) | 6.0092 |
Shunt resistance (Rsh) | 269.5934 Ω |
Series resistance (Rs) | 0.37152 Ω |
Frequency (F) | 50 HZ |
X/R Ratio | 7 |
Grid Voltage (RMS) | 500 V |