Table 5.
Concordance of observers' second scenogram obstruction diagnoses with the final diagnosis, n (%)
|
Mechanical obstruction by final diagnosis
|
Specificity, % | Sensitivity, % | PPV, % | NPV, % | Accuracy, % | |||
|
Yes
|
None
|
Total
|
||||||
| I Observer | ||||||||
| Yes | 34 (81) | 4 (100) | 38 (82.6) | 81 | 0 | 88.47 | 0 | 73.91 |
| None | 8 (19) | 0 (0) | 8 (17.4) | |||||
| II Observer | ||||||||
| Yes | 32 (76.2) | 4 (100) | 36 (78.3) | 76.19 | 0 | 88.88 | 0 | 69.56 |
| None | 10 (23.8) | 0 (0) | 10 (21.7) | |||||
| III Observer | ||||||||
| Yes | 35 (83.3) | 2 (50) | 37 (80.4) | 83.33 | 50 | 94.59 | 22.23 | 80.43 |
| None | 7 (16.7) | 2 (50) | 9 (19.6) | |||||
| Total | 42 (91.3) | 4 (8.7) | 46 (100) | |||||