Skip to main content
. 2023 Oct 25;1(2):qyad035. doi: 10.1093/ehjimp/qyad035

Figure 7.

Figure 7

Estimated and actual end-diastolic pressures. Pairwise comparison of VE, SW, MEP, and EPEV, computed using an assumed EDP of 7.5 mmHg compared to using the true value from invasive measurements. No significant differences were seen.