Table 2. The time spent in mediastinal lymph node dissection.

Lymph nodes Traditional aspirator, mean ± SD (s) New aspirator, mean ± SD (s) P
No. 2/4R 544.71±120.80 507.54±100.00 0.008
No. 7R 507.11±104.61 465.09±94.94 0.001
No. 7L 608.47±128.50 549.39±102.11 <0.001

SD, standard deviation; s, seconds.