Skip to main content
. 2023 Nov 11;18:122. doi: 10.1186/s13000-023-01412-x

Table 3.

Evaluation of paired-biopsy samples

Matched Pair Modified Marsh Score Continuous Machine Learning Score
Pre- Biopsy Post- Biopsy Manual Score Response Pre- Biopsy Post- Biopsy Alignment with Manual Score
1 3b 0 Yes 3.95 1.63 Yes
2 3a 0 Yes 0.82 −0.20 Yes
3 3b 0 Yes 2.44 0.11 4 Yes
4 3b 1 Yes 2.22 0.21 Yes
5 3a 3a No 2.46 3.49 No
6 3b 0 Yes 3.78 −0.21 Yes
7 3b 0 Yes 2.85 1.52 Yes
8 3a 0 Yes 2.65 0.02 Yes
9 3b 0 Yes 2.44 1.15 Yes
10 1 0 Yes 1.57 0.78 Yes
11 3b 3a Yes 3.48 1.65 Yes
12 3b 0 Yes 3.56 0.61 Yes
13 3b 1 Yes 2.80 1.51 Yes
14 3a 0 Yes 3.56 0.56 Yes
15 3a 0 Yes 1.27 0.55 Yes
16 2 1 Yes 2.28 0.93 Yes
17 3b 0 Yes 2.36 1.65 Yes
18 3b 0 Yes 4.28 0.40 Yes
19 3a 0 Yes 2.60 0.00 Yes
20 3b 0 Yes 1.70 0.98 Yes
21 3c 3b Yes 3.71 1.70 Yes
22 3a 0 Yes 1.80 0.78 Yes
23 3b 0 Yes 3.06 −1.23 Yes
24 3b 0 Yes 2.96 0.71 Yes
25 3a 0 Yes 2.51 0.47 Yes
26 3b 0 Yes 3.38 0.87 Yes
27 3b 3a Yes 3.02 1.96 Yes
28 3b 0 Yes 3.13 1.13 Yes