Univariate and multivariate linear regression analyses of baseline determinates of the left ventricular ejection fraction reduction

Variables Univariate analysis Multivariate analysis
Beta SE P-value Beta SE VIF P-value
Constant 38.61 11.02 <0.001
Age, years 0.232 0.149 0.126
Male −7.557 3.336 0.028
Baseline QRSd, ms 0.100 0.064 0.131
Strauss LBBB 4.519 3.597 0.215
QRSd reduction, ms 0.213 0.095 0.030 0.174 0.086 1.089 0.048
Capture of LBB 6.937 3.354 0.044
Stim-V6 RWPT −0.227 0.132 0.092
Baseline LVEDD, mm −0.488 0.181 0.009 −0.409 0.166 1.085 0.017
eGFR, mL/min −0.061 0.084 0.468
Atrial fibrillation −10.250 4.698 0.034
Septal LGE percentage, (%) −0.624 0.158 <0.001 −0.463 0.159 1.138 0.005
Global LGE percentage, (%) −0.473 0.152 0.003
Lateral LGE percentage, (%) −0.288 0.108 0.010