Implant geometries related to the bone densities [22,47,102].

Titanium Implant Macrogeometry Microgeometry
(Thread Design)
Bone Density Implant Placement Condition Shape Diameter Length Shape Pitch Width Depth
High -
  • -

    Cylindrical

  • -

    Conical

  • -

    Hybrid design (apical conical and crestal cylindrical)

All All
(≥6 mm)
  • -

    V-thread

  • -

    Square thread

  • -

    Buttress thread

Standard (1.2 mm) Standard (0.18–0.30 mm) Standard (0.42 mm)
Low -
  • -

    Conical

  • -

    Conical with crestal back taper

  • -

    Cylindrical design with apical taper

Wider
(≥4 mm)
Longer
(9–11 mm)
  • -

    Reverse buttress

  • -

    Self-tapping

🡇
Lower than the standard
Standard 🡅
Higher than the standard
- Immediate
  • -

    Conical

≥4 mm ≥11 mm
  • -

    Self-tapping

- - -