Skip to main content
. 2023 Oct 26;15(21):5153. doi: 10.3390/cancers15215153

Table 2.

ROC analysis for predictors of the LAD Dmax > 10 Gy and LAD Dmean > 4 Gy.

LAD Dmax > 10 Gy Cut-off Value AUC 95%IC p Value
Minimum distance from LAD to tangent fields ≤−0.11 cm 0.714 0.614–0.801 <0.0001
Lung Volume ≤1087.7 cc 0.626 0.553–0.695 0.002
Heart volume >655.51 cc 0.660 0.497–0.799 0.07
LAD Dmean > 4 Gy Cut-off Value AUC 95%IC p Value
Minimum distance from LAD to tangent fields <0.49 cm 0.687 0.588–0.744 0.001
Breast separation >16.1 cm 0.649 0.550–0.740 0.008
Heart volume >652.6 cc 0.672 0.508–0.810 0.051
Lung volume ≤1190.6 cc 0.624 0.519–0.722 0.050

ROC comparison curves of variables predicting a LAD maximum dose > 10 Gy and a LAD mean dose > 4 are shown in Figure 2. The minimum distance of LAD from tangent open fields was the strongest predictor of both the LAD mean and maximum dose.