Skip to main content
. 2023 Oct 26;15(21):5153. doi: 10.3390/cancers15215153

Table 3.

Predictors of the LAD Dmax > 10 and LAD Dmean > 4.

FB Scans Predictors of LAD Dmax > 10 PPV (%)
Minimum distance from LAD to tangent fields ≤−0.1 cm 73
Minimum distance from LAD to tangent fields ≤−0.1 + Heart volume >655.5 cc 87
Minimum distance from LAD to tangent fields <−0.1 + Heart Volume >655.5 cc + Lung Volume ≤1087.7 91
FB Scans Predictors of LAD Dmean > 4 PPV (%)
Minimum distance from LAD to tangent fields <0.5 cm 79
Minimum distance from LAD to tangent fields <0.5 cm + Breast separation >16.1 cm 91
Minimum distance from LAD to tangent fields <0.5 cm + Breast separation >16.1 cm + Heart volume >652.6 cc 96
Minimum distance from LAD to tangent fields <0.5 cm + Breast separation >16.1 + Heart volume >652.6 cc + Lung volume ≤1190.6 98