Skip to main content
. 2023 Nov 3;8(45):43000–43007. doi: 10.1021/acsomega.3c06226

Table 2. Calculated Activation Energy (Ea) Using Arrhenius Plot at Different Regression Factors (R. F.).

no. R. F. (%) Ea (kJ/mol) TG (%)
1 10 199.07 97.67
2 20 167.71 95.27
3 30 149.63 92.88
4 40 138.15 90.49
5 50 129.69 88.09
6 60 122.15 85.70
7 70 111.44 83.30
8 80 89.10 80.91
9 90 153.49 78.52