Table 3. Experimental Operating Conditions for Simultaneous Removal of SO3 and Mercury.
indicators | parameters |
---|---|
flue gas flow rate (m3/h) | 3500 |
absorbent/SO3 molar ratio | 0.74 |
residence time (s) | 0.5 |
absorbent | a mixture of 27.2 kg/h ZnO and 8.4 kg/h CuS |
inlet temperature of first heat exchanger | 277 °C |
outlet temperature of first heat exchanger | 178 °C |
inlet temperature of secondary heat exchanger | 180 °C |
outlet temperature of secondary heat exchanger | 156 °C |