Skip to main content
. 2023 Nov 20;11(4):171. doi: 10.3390/diseases11040171

Table 1.

True positives (TPs), true negatives (TNs), false positives (FPs), and false negatives (FNs) for the radiologist and AI system.

TPs
(n, %)
TNs
(n, %)
FPs
(n, %)
FNs
(n, %)
COVID-19+ vs. healthy
(n = 2140)
Radiologist 1450 (67.8) 503 (23.5) 127 (5.9) 60 (2.8)
AI 1419 (66.3) 515 (24.1) 127 (5.9) 79 (3.7)
Pneumonia+ vs. healthy (n = 1500) Radiologist 1218 (81.2) 235 (15.6) 32 (2.2) 15 (1)
AI 1191 (79.4) 234 (15.6) 45 (3) 30 (2)