Table 4.
Diagnostic performance for classification of vascular injury in solid organ from blunt abdominal trauma (isolated pseudoaneurysm vs pseudoaneurysm with low velocity extravasation or active bleeding) using angiography as the reference standard.
| Sensitivity | Specificity | Positive predictive value | Negative predictive value | Accuracy | |
|---|---|---|---|---|---|
| CEUS | 96.67% | 87.50% | 96.67% | 87.50% | 94.74% |
| MDCT | 93.33% | 75.00% | 93.33% | 75.00% | 89.47% |
CEUS = contrast-enhanced ultrasound, MDCT = multidetector computed tomography.