Skip to main content
. 2023 Apr 5;56(6):802–811. doi: 10.5946/ce.2022.211

Table 2.

Outcomes of endoscopic ultrasound-guided hepaticogastrostomy and transmural stenting

PS (n=109) cSEMS (n=43) p-value
Functional success, yes 93 (85.3) 41 (95.3) 0.149
Punctured bile duct 0.007
 B2 71 (65.1) 17 (39.5)
 B3 38 (34.9) 26 (60.5)
Tract dilator <0.001
 Mechanical 64 (58.7) 12 (27.9)
 Balloon 19 (17.4) 17 (39.5)
 Electrocautery 15 (13.8) 14 (32.6)
 None 11 (10.1) 0 (0)
EUS-HGAS, yes 26 (23.9) 5 (11.6) 0.144
Procedure time (min) 30.0 (8.0–187.0) 41.0 (15.0–150.0) 0.125

Values are presented as number (%) or median (range).

PS, plastic stent; cSEMS, fully/partially covered self-expandable metallic stent; B2, segment 2 bile duct; B3, segment 3 bile duct; EUS-HGAS, combined endoscopic ultrasound-guided antegrade stenting with endoscopic ultrasound-guided hepaticogastrostomy and transmural stenting.