Table 5.
Parameters | Clock Drawing Test Score | p-Value | |
---|---|---|---|
0 | 2 | ||
BCVA, LogMAR | 0.38 ± 0.56 | 0.20 ± 0.44 | <0.0001 ** |
SERE, D | −1.4 ± 2.6 | −2.2 ± 3.3 | 0.011 * |
MD, dB | −8.9 ± 6.2 | −7.9 ± 5.9 | 0.18 |
PSD, dB | 7.3 ± 3.9 | 8.2 ± 4.6 | 0.031 * |
FL, % | 11.2 ± 14.3 | 9.7 ± 11.8 | 0.21 |
FN, % | 9.6 ± 10.8 | 5.6 ± 8.0 | <0.0001 ** |
FP, % | 3.3 ± 4.9 | 2.2 ± 3.4 | 0.0022 ** |
Data are expressed as mean ± standard deviation. p-values are calculated by unpaired t-tests. * and ** indicate p < 0.05 and p < 0.01, respectively. BCVA, best-corrected visual acuity; LogMAR, logarithm of minimal angle of resolution; SERE, spherical equivalent refractive error; D, diopter; MD, mean deviation; PSD, pattern standard deviation; dB, decibel; FL, fixation loss; FN, false negative; FP, false positive.