Skip to main content
. 2023 Nov 10;23(22):9087. doi: 10.3390/s23229087

Table 5.

A comparison of leak size identification using the three methods under the pressure of 13 bar.

Method Accuracy (%) Average Accuracy (%)
0.3 mm 0.5 mm 1 mm
TD-CNN 68.5 75 100.0 79.6
Banjara et al. adaptation 81.6 95.9 100.0 92.2
The proposed method 100.0 100.0 100.0 100.0