Table 6.
A comparison of leak size identification using the three methods under the pressure of 18 bar.
Method | Accuracy (%) | Average Accuracy (%) | ||
---|---|---|---|---|
0.3 mm | 0.5 mm | 1 mm | ||
TD-CNN | 64.4 | 67.6 | 100.0 | 75.9 |
Banjara et al. adaptation | 97.0 | 45.0 | 100.0 | 87.0 |
The proposed method | 98.6 | 99.5 | 99.5 | 99.2 |