Skip to main content
. 2023 Nov 10;23(22):9087. doi: 10.3390/s23229087

Table 6.

A comparison of leak size identification using the three methods under the pressure of 18 bar.

Method Accuracy (%) Average Accuracy (%)
0.3 mm 0.5 mm 1 mm
TD-CNN 64.4 67.6 100.0 75.9
Banjara et al. adaptation 97.0 45.0 100.0 87.0
The proposed method 98.6 99.5 99.5 99.2