Table 2.

Performance of pathologists and the computer in determining CD3+ T cell coverage

PATHOLOGIST 1 PATHOLOGIST 2 PATHOLOGIST 3 PATHOLOGIST 4 COMPUTER
Mean pA ± SD 26.3 ± 22.6 20.4 ± 16.1 29.5 ± 24.6 21.7 ± 23.0 19.0 ± 13.5
Bias ± SD 2.4 ± 12.3 −10.0 ± 9.6 1.9 ± 11.8 −5.6 ± 11.3 −8.3 ± 5.6
CCC (95% C.I.) 0.79 (0.61, 0.89) 0.73 (0.50, 0.86) 0.84 (0.70, 0.92) 0.81 (0.64, 0.91) 0.81 (0.67, 0.90)
Rank Corr. (95% C.I.) 0.90 (0.77, 0.96) 0.85 (0.65, 0.94) 0.96 (0.89, 0.98) 0.99 (0.97, 1.00) 0.96 (0.91, 0.99)
Pearson Corr. (95% C.I.) 0.86 (0.67, 0.94) 0.86 (0.68, 0.94) 0.90 (0.76, 0.96) 0.89 (0.73, 0.96) 0.97 (0.91, 0.99)