Electrochemical parameters of symmetric dummy cells.
CE | R s (Ω) | R ct (Ω) | J 0 (mA cm−2) | J lim (mA cm−2) |
---|---|---|---|---|
Pt | 7.10 | 2.85 | 5.25 | 15.14 |
CNTs | 30.97 | 14.39 | 0.78 | 19.50 |
C/T-0.5 wt% | 28.87 | 8.74 | 2.10 | 20.42 |
C/T-1.0 wt% | 29.07 | 6.64 | 2.74 | 22.39 |
C/T-2.0 wt% | 31.54 | 7.76 | 1.35 | 20.41 |