Table 2. Solar Field Design without Thermal Storage: Inputs and Calculation Results.

receiver inlet pipe diameter, Di 0.065 m
receiver outlet pipe diameter, Do 0.07 m
receiver area, Ar 31.27 m2
collector effective length, Lc 142.2 m
collector width, Wc 5.75 m
collector aperture area, Aa 817.5 m2
direct normal irradiance, DNI 10.80 kWh/m2
sunlight hours per day, td 12 h
receiver absorbance, a 0.94
receiver reflectance, r 0.92
receiver intercept factor, g 0.92
receiver transmittance, t 0.945
incident angle modifier, k 1
absorbed solar radiation, S 0.677 kW/m2
heat loss coefficient, UL 0.0055 kW/m2°C
collector heat removal factor, FR 0.963
HTF outlet temperature, To 265 °C
HTF inlet temperature, Ti 165 °C
HTF average temperature, Tav 236 °C
ambient temperature, Ta 31 °C
HTF mass flow per loop, mc 7.0 kg/s
HTF heat capacity at Tav, Cp 1.8 kJ/kg K
collector useful heat gain, Qc 510 kJ/s
HTF first collector outlet temperature, Toc 207 °C
number of collectors per loop, NL 3
solar field total number of loops, L 1
solar field number of collectors, Nf 3
solar field area, As 2452 m2
HTF mass flow in the solar field, mT 7.0 kg/s