Skip to main content
. 2023 Dec 1;14:7950. doi: 10.1038/s41467-023-43762-6

Table 2.

Important parameters that should be reported to ensure reproducibility

Catalysts Electrodes Electrolysis Cells
Composition of the material (also including impurities) Composition of the electrode Compression of the cell
Particle size distribution, polarity Detailed assembly method incl. ink recipe and preparation Operation mode of the cell (single pass, semi batch, batch)
Materials morphology, aggregation state In-plane and through-plane electrical conductivity of the electrode Membrane used and its pretreatment
Post-mortem analysis of the catalysts via spectroscopy, diffractometry and microscopy methods as well as operando studies to observe any catalyst changes Data sheet of manufacturer of materials used— link to product or product numbers Thickness of each individual component (e.g., porous transport layer)
[Approximate cost for 1 g, 1 kg of electrocatalyst] Porosity, adhesion, surface roughness and lateral homogeneity Periphery applied (e.g., humidification & purification systems, ion exchange systems used for water purification)
Water sorption and contact angle Temperature inside and outside of the cell
Electrode thickness Geometry of flow fields used
Active area of used electrodes—geometric flow rate in respect to active area, reporting on the occurrence of delamination Measurement protocol
ICP-OES analysis of the used electrolyte and anolyte
Schematics of used cells