Skip to main content
. 2020 Mar 1;22(2):119–125. doi: 10.51893/2020.2.oa1

Table 4.

Serial nasopharyngeal and tracheal viral loads

2 Days before intubation Day of intubation 2 Days after intubation 1 Week after intubation
Patient A Nasopharynx (log copy/mL) 6.80 5.99 6.84 3.51
Tracheal aspirate (log copy/mL) Na 7.30 7.31 4.62
Patient B Nasopharynx (log copy/mL) 4.75 3.17 Negative Negative
Tracheal aspirate (log copy/mL) na 6.33 6.70 5.26

The severe acute respiratory syndrome coronavirus (SARS-CoV-2) detection limit of real-time reverse transcriptase polymerase chain reaction was 2.84 log copies/mL.