Skip to main content
. 2023 Nov 13;10:1250311. doi: 10.3389/fcvm.2023.1250311

Table 2.

Mean values and standard deviation of conventional GLS and AI-automated GLS at individual timepoints during trastuzumab therapy.

T0 T1 T2 T3 T4 T5
GLS (CON) −20.1 ± 2.6 −19.0 ± 2.8 −18.8 ± 2.3 −18.3 ± 2.3 −19.1 ± 1.9 −19.3 ± 2.5
GLS (AI) −19.0 ± 2.2 −18.6 ± 1.8 −18.2 ± 2.7 −17.3 ± 3.2 −18.1 ± 2.4 −18.4 ± 2.0
A4C (CON) −20.0 ± 3.1 −19.0 ± 3.2 −18.9 ± 2.7 −18.6 ± 3.0 −19.1 ± 2.3 −19.4 ± 2.6
A4C(AI) −19.8 ± 3.9 −19.4 ± 4.0 −18.5 ± 3.5 −18.8 ± 3.7 −19.3 ± 3.1 −19.1 ± 3.1
A2C CON) −20.8 ± 2.9 −19.2 ± 3.7 −18.5 ± 4.1 −18.8 ± 2.7 −19.6 ± 2.4 −20.0 ± 3.5
A2C (AI) −20.7 ± 4.2 −19.2 ± 4.2 −18.4 ± 3.9 −18.1 ± 3.2 −19.1 ± 4.4 −19.7 ± 4.1
A3C CON) −19.6 ± 3.1 −18.8 ± 3.8 −18.8 ± 2.5 −18.3 ± 2.9 −19.3 ± 2.8 −18.8 ± 3.3
A3C (AI) −15.3 ± 3.0 −15.5 ± 2.0 −15.7 ± 3.5 −13.9 ± 3.7 −15.5 ± 2.8 −14.9 ± 3.7
LVEF (CON) 61.5 ± 4.6 59.8 ± 5.7 58.7 ± 6.6 58.5 ± 6.3 58.9 ± 5.7 59.5 ± 5.7
LVEF (AI) 63.4 ± 6.9 62.4 ± 6.7 58.8 ± 9.2 58.9 ± 8.7 58.9 ± 7.4 62 ± 6.0

Data are expressed as mean ± standard deviation.

AI, artificial intelligence; A4C, apical-four chamber; A2C, apical-two chamber; A3C, apical-three chamber; CON, conventional; GLS, global longitudinal strain; LVEF, left ventricular ejection fraction.