TABLE 2.
Summary of DC-SIGN/R binding experimentsa
| Analyte | Oligomer state | Ligand | Analyte (μM) | Measured KD | Monomer adjusted KD |
|---|---|---|---|---|---|
| DC-SIGN R CRD | Monomer | gp120 (Th14-12) | 50.0-0.097 | 2.9 | 2.9 |
| DC-SIGN R R8 | Monomer | gp120 (IIIB) | 3500-0.488 | 3.9 | 3.9 |
| DC-SIGN R R5 | Mono/Tetra | gp120 (IIIB) | 1000-0.96 | 10.4 | 10.4 |
| DC-SIGN R R1 | Tetramer | gp120 (IIIB) | 50-0.0097 | 0.008 | 0.002 |
| DC-SIGN R R1 | Tetramer | gp120 (Th14-12) | 0.8-0.025 | 0.022 | 0.005 |
| DC-SIGN R R1 | Tetramer | gp120 (NL4-3) | 0.8-0.025 | 0.029 | 0.007 |
| DC-SIGN R R1 | Tetramer | gp120(92Ug21-9) | 0.8-0.025 | 0.031 | 0.008 |
| DC-SIGN CRD | Monomer | gp120 (NL4-3) | 500-1.95 | 50.8 | 50.8 |
| DC-SIGN R8 | Monomer | gp120 (NL4-3) | 500-0.488 | 86.5 | 86.5 |
| DC-SIGN R1 | Tetramer | gp120 (NL4-3) | 50-0.97 | 9 | 2.3 |
| DC-SIGN R R8 | Monomer | ICAM-3-Fc | 500-0.488 | 54 | 54 |
| DC-SIGN R R5 | Mono/Tetra | ICAM-3-Fc | 1000-0.96 | 100-200 | 100-200 |
| DC-SIGN R R1 | Tetramer | ICAM-3-Fc | 50.0-0.0097 | 62 | 15 |
| DC-SIGN R R1 | Tetramer | ICAM-2-Fc | 250-0.097 | ND | ND |
| DC-SIGN R R1 | Tetramer | ICAM-1-Fc | 250-0.097 | ND | ND |
| DC-SIGN CRD | Monomer | ICAM-3-Fc | 500-1.95 | 331 | 29.1 |
| DC-SIGN R8 | Monomer | ICAM-3-Fc | 500-0.488 | >500 | >500 |
| DC-SIGN R1 | Tetramer | ICAM-2-Fc | 50-6.25 | ND | ND |
| DC-SIGN R1 | Tetramer | ICAM-3-Fc | 63-3.91 | 4.6 | 1.1 |
| DC-SIGN CRD | Monomer | FcγRIII (CD16) | 500-0.488 | 10.5 | 10.5 |
| DC-SIGN R1 | Tetramer | FcγRIII (CD16) | 250-0.488 | 421.5 | 16.0 |
| DC-SIGN R R1 | Tetramer | FcγRIII (CD16) | 250-3.9 | 15.8 | 3.95 |
| DC-SIGN R R1 | Tetramer | FcγRIIb (CD32) | 250-0.487 | 33.5 | 8.37 |
Ligand immobilization levels and concentration range of injected analyte are indicated. For comparison, monomer KD values were divided by respective receptor oligomerization states. All concentrations and dissociation constants represented as 1 × 10 M−6 (μM) unless otherwise indicated. Each binding experiment was performed with serial 2× dilutions of analyte and is representative of either multiple single-injection experiments or averaged triplicate injections. ND, nondetectable; Mono/Tetra, monomer-tetramer.