Skip to main content
. 2023 Oct 4;30(6):765–776. doi: 10.1007/s10140-023-02174-1

Table 1.

Characteristics of the included studies and patients

First author, year of publication Country Study design Age (years) Male (%) CT type CT device/Slice thickness Contrast material
Augustin, 2019 France Prospective cohort NS NS Thoracoabdominal A 64-row MDCT scanner/0.625 mm NS (IV)
Bodanapally, 2009 United States Retrospective cohort 29.6, (13–86) Mean, (Range) 86 Thoracic, Thoracoabdominopelvic, Abdominopelvic MX 8000 or Brilliance 16 Power; Philips Medical Systems, Cleveland, OH (a 4- or 16-slice CT system)/3–5 mm 2% sodium diatrizoate (Hypaque sodium; Nycomed, Princeton, NJ); 600 ml IV and 1–1.5 L enema
Dreizin, 2013 United States Case–control 32.6, (16–85) Mean, (Range) 92.6 Thoracoabdominal Somatom; Siemens, Malvern, Pa (64-section MDCT)/1.5 mm 103 mL of IV ioversol, Optiray; Mallinckrodt, Hazelwood, Mo
Daza-Cajas, 2021 Colombia Prospective cohort 23.2, (18–37) Mean, (Range) 90.75 Thoracic, Abdominal, Thoracoabdominal GE LightSpeed; GE Healthcare, Milwaukee, WI, USA; 64 rows of detectors/ < 3 mm NS (Non-contrast, IV or oral)
Leung, 2015 Canada Case–control NS NS Abdominal a 64-slice MDCT scanner/3 mm 125 mL IV Omnipaque 300, GE Healthcare
Melo, 2011 Brazil Prospective cohort 24.3, (6.8), (14–44) Mean, (SD), (Range) 96.77 Thoracoabdominal GE LightSpeed; GE Healthcare, Milwaukee, WI, USA; 8 rows of detectors/1.25 mm 100 mL IV iobitridol, Henetix 300, Guerbet, Rio de Janeiro, Brazil; 400 mL oral iodinated contrast solution; 200 mL of the same solution rectally
Stein, 2007 United States Retrospective cohort 29.6, (11.4), (13–86) Mean, (SD), (Range) 87.7 Thoracic, Abdominal, Thoracoabdominal MX 8000 or Brilliance 16 Power; Philips Medical Systems, Cleveland, OH (a 4- or 16-slice MDCT scanner)/3 mm Oral, rectal and 150 mL of I2 mg/mL of IV contrast material
Uhlich, 2018 United States Retrospective cohort NS NS NS Koninklijke Philips NV, Amsterdam; a 256-slice CT scanner, and Philips Brilliance Power; a 64-slice machine/NS NS
Yucel, 2015 Turkey Prospective cohort 30, (15–61) Mean, (Range) 91 Thoracoabdominal Multislice CT scanner NS

GE General Electric, IV Intravenous, MDCT Multidetector computed tomography, NS Not specified