Skip to main content
. 2023 Dec 4;142(3):e2022415. doi: 10.1590/1516-3180.2022.0415.R2.310523

Table 2. Operative characteristics of neck circumference for obstructive sleep apnea screening compared to polysomnography.

Operative characteristics for neck circumference ≥ 40 cm Operative characteristics at the optimal cut-off point

Sensitivity (%) 95%CI Specificity (%) 95%CI AUC Cut-off point (cm) Sensitivity (%) 95%CI Specificity (%) 95%CI AUC
Women general 20.3 (14.6–27.1) 87.7 (82.8–91.6) 0.54 (0.50–0.57) 36.5 71.7 (64.3–78.3) 55.3 (48.7–61.8) 0.63 (0.59–0.68)
Men general 64.5 (58.1–70.5) 52.4 (46.7–58.1) 0.58 (0.54–0.62) 41.0 56.0 (49.5–62.2) 62.0 (56.1–67.2) 0.59 (0.54–0.63)
Women
< 60 18.0 (10.9–29) 91.0 (85.1–95.1) 0.54 (0.5–0.59) 36.5 65.1 (53.5–75.3) 64.6 (56.2–72.4) 0.65 (0.58–0.71)
> 60 27.2 (18.4–37.4) 74.7 (64.5–83.3) 0.50 (0.44–0.57) 38.5 55.0 (43.5–65.4) 61.0 (49.9–71.2) 0.58 (0.50–0.65)
Men
< 60 69.7 (61.5–77.1) 54.2 (45.7–62.5)) 0.61 (0.56–0.67) 40.5 69.7 (61.5–77.1) 55.6 (47.1–63.8) 0.63 (0.57–0.68)
> 60 57.3 (47.2–67) 50.9 (43.1–58.7) 0.54 (0.48–0.60) 39.0 73.8 (64.2–82) 42.5 (34.9–50.4) 0.58 (0.52–0.63)

AUC = area under the curve; CI = confidence interval.