Table 3. Operative characteristics of waist circumference for obstructive sleep apnea screening compared to polysomnography.

x Operative characteristics for optimal cut-off point found in the study

  Sensitivity (%) 95%CI Specificity (%) 95%CI AUC Cut-off point cm Sensitivity (%) 95%CI Specificity (%) 95%CI AUC
Women general 82.6 (76–87.9) 42.1 (35.7–48.7) 0.62 (0.58–0.66) 97.5 65.3 (57.7–72.4) 68.5 (62.2–74.4) 0.67 (0.62–0.71)
Men general 83.7 (78.4–88.1) 23.8 (19.2–28.9) 0.54 (0.50–0.57) 99.5 53.1 (46.6–59.4) 58.0 (52.2–63.4) 0.55 (0.51–0.59)
Women
< 60 81.3 (71–89.1) 45.8 (37.5–54.3) 0.63 (0.57–0.69) 94 65.0 (53.5–75.3) 64.0 (55.5–71.7) 0.64 (0.57–0.71)
> 60 83.7 (74.5–90.6) 36.3 (26.4–47) 0.60 (0.53–0.66) 97.5 73.1 (62.9–81.8) 59.3 (48.5–69.5) 0.66 (0.59–0.73)
Men
< 60 85.2 (78.3–90.6) 27.8 (20.6–35.8) 0.56 (0.51–0.61) 98.5 58.0 (49.4–65.9) 60.0 (51.6–67.7) 0.59 (0.53–0.64)
> 60 81.6 (72.7–88.5) 20.4 (14.5–27.3) 0.51 (0.64–0.55) 99.5 52.4 (42.4–62.4) 55.1 (47.2–62.8) 0.53 (0.47–0.59)