Skip to main content
. 2023 Nov 27;14:1246892. doi: 10.3389/fphar.2023.1246892

TABLE 3.

Subject’s individual liver enzyme values (in units per L; U/L) at baseline (−30 min) and after the session (300 min) are displayed for day 4 (largest dose). ASAT/GOT, aspartate aminotransferase/glutamic oxaloacetic transaminase; ALAT/GPT, alanine transaminase/glutamate-pyruvate transaminase; GAMMA-GT, gamma-glutamyl transferase.

Liver enzymes
Day 4 Subject (#)
Timepoint Analyt Reference #3 #4 #5 #6 #7 #8 #9 #10
Baseline (t-30) ASAT/GOT (U/L) <37 17 22 21 17 23 17 17 20
ALAT/GPT (U/L) <65 18 16 23 24 20 24 16 31
GAMMA-GT (U/L) <85 17 15 17 18 16 18 14 14
After session (t300) ASAT/GOT (U/L) <37 19 25 20 29 23 18 16 20
ALAT/GPT (U/L) <65 17 17 23 25 20 25 16 36
GAMMA-GT (U/L) <85 16 15 16 18 17 19 12 16

The bold numbers indicate the clinical threshold values. Concentrations higher than the reference values indicate a clinically relevant increase in the liver enzyme concentration.