Table 4.

Characteristics of action potential and low-loaded shortening in the ENDO and EPI models, compared to experimental data [23]

APD90 exp [34 ± 1 °C], ms APD90 mod, ms T max exp [34 ± 1 °C], ms T max mod, ms TR75 exp [34 ± 1 °C], ms TR75 mod, ms
ENDO 272 ± 11 [23] 287 158 ± 5 [23] 186 119 ± 8 [23] 102
EPI 221 ± 8 [23] 217 126 ± 3 [23] 133 91 ± 5 [23] 71
1.23 1.32 1.25 1.40 1.31 1.44