Skip to main content
. 2016 Apr 6;66(6):463–476. doi: 10.1007/s12576-016-0441-8

Table 1.

General electrical properties of the two groups of AFSC approached via whole-cell patch-clamp

Feature R p (MΩ) C m (pF) R m (MΩ) R a (MΩ) τ (μs) I hold (pA) Preservation of the seal at the end of exp.
Senescent AFSC (n = 18)
 Mean 2.03 47.27 2021.34 7.62 370.55 −179.17 72.22 %
 SD 0.83 22.28 2253.96 4.44 291.41 295.54
Cryopreserved AFSC (n = 19)
 Mean 2.33 44.97 1519.67 8.92 415.46 −100.95 78.94 %
 SD 0.77 26.75 1927.00 4.24 330.09 95.71

R p pipette resistance, C m membrane capacitance, R m membrane resistance, R a access resistance, τ time constant of the equivalent electrical circuit, I hold holding current at −80 mV