Table 3.
BAV | TAV | P Value | |
---|---|---|---|
Sinus of Valsalva (mm) | |||
At baseline | 34.6 ± 0.9 | 32.3 ± 0.5 | 0.022 |
Direct preoperatively | 36.3 ± 0.7 | 33.5 ± 0.5 | 0.009 |
Immediate postoperatively | 36.5 ± 0.8 | 33.7 ± 0.4 | <0.001 |
Last follow-up | 36.8 ± 0.7 | 34.2 ± 0.6 | 0.012 |
Sinotubular junction (mm) | |||
At baseline | 30.7 ± 0.7 | 28.5 ± 0.6 | 0.041 |
Direct preoperatively | 31.8 ± 0.9 | 28.4 ± 0.6 | <0.001 |
Immediate postoperatively | 31.9 ± 0.8 | 28.6 ± 0.5 | <0.001 |
Last follow-up | 32.8 ± 0.7 | 29.0 ± 0.5 | <0.001 |
Ascending aorta (mm) | |||
At baseline | 34.8 ± 0.8 | 31.5 ± 0.6 | <0.001 |
Direct preoperatively | 36.8 ± 0.9 | 32.2 ± 0.6 | <0.001 |
Immediate postoperatively | 37.1 ± 0.6 | 32.7 ± 0.5 | <0.001 |
Last follow-up | 38.9 ± 0.7 | 34.7 ± 0.7 | <0.001 |
Data are presented as n (%) or mean ± SD or median.
BAV = bicuspid aortic valve; TAV = tricuspid aortic valve.