Skip to main content
. 2023 Nov 25;49:101313. doi: 10.1016/j.ijcha.2023.101313

Table 3.

Aorta diameters by MDCT at baseline, direct preoperatively, immediate postoperatively, and at the last follow-up.

BAV TAV P Value
Sinus of Valsalva (mm)
At baseline 34.6 ± 0.9 32.3 ± 0.5 0.022
Direct preoperatively 36.3 ± 0.7 33.5 ± 0.5 0.009
Immediate postoperatively 36.5 ± 0.8 33.7 ± 0.4 <0.001
Last follow-up 36.8 ± 0.7 34.2 ± 0.6 0.012



Sinotubular junction (mm)
At baseline 30.7 ± 0.7 28.5 ± 0.6 0.041
Direct preoperatively 31.8 ± 0.9 28.4 ± 0.6 <0.001
Immediate postoperatively 31.9 ± 0.8 28.6 ± 0.5 <0.001
Last follow-up 32.8 ± 0.7 29.0 ± 0.5 <0.001



Ascending aorta (mm)
At baseline 34.8 ± 0.8 31.5 ± 0.6 <0.001
Direct preoperatively 36.8 ± 0.9 32.2 ± 0.6 <0.001
Immediate postoperatively 37.1 ± 0.6 32.7 ± 0.5 <0.001
Last follow-up 38.9 ± 0.7 34.7 ± 0.7 <0.001

Data are presented as n (%) or mean ± SD or median.

BAV = bicuspid aortic valve; TAV = tricuspid aortic valve.